![](/images/new-backgrounds/1122910/12291045x1.webp)
SW-D1 No. 1 ~ No. 4 Number of rings for auto receive
When the machine is set in the auto receive mode, the number of rings before answering can be selected. It may be set from one to nine rings using a binary number. Since the facsimile telephone could be used as an ordinary telephone if the handset is taken off the hook, it should be programmed to the user’s choice. If the soft switch was set to 1, direct connection is made to the facsimile. If a facsimile calling beep was heard when the handset is taken off the hook, press the START key and put the handset on the hook to have the facsimile start receiving. If it was set to 0 accidentally, receive ring is set to 1.
NOTE: If the machine is set to answer after a large number of rings, it may not be able to receive faxes successfully. If you have diffi- culty receiving faxes, reduce the number of rings to a maximum of 5.
SW-D1 No. 5 Automatic switching manual to auto receive mode
This soft switch is used to select whether the machine should switch to the auto receive mode after 5 rings in the manual receive mode or re- main in the same way as
SW-D1 No. 6 ~ No. 8 Reserved
Set to "0".
SW-D2 No. 1 ~ No. 5 Reserved
Set to "0".
Set the minimum time period of CI signal interruption which affords to be judged as a CI OFF section.
A | B |
400msec2000msec
12
SW-D2 No. 8 Reserved
Set to "0".
SW-E1 No. 1 Tel/Fax Automatic switching mode
Used to set auto TEL/FAX switching mode or to set the normal fax mode.
Choice is made as to how long to rumble the dummy ringer on TEL/FAX automatic switching mode.
Used for detection of CNG in one tone or two tones in the TEL/FAX automatic switching mode.
SW-E1 No. 5 CNG detect time at TEL/FAX mode
The switch which sets the time from the start of CNG detection to the end of detection.
SW-E1 No. 6 ~ No. 8 Reserved
Set to "0".
SW-E2 No. 1 ~ No. 4 Pseudo ringer sound output level to the line
Used to adjust sound volume of pseudo ringer to the line (ring back tone) generated on selecting TEL/FAX. Setting is the reduce level from
SW-E2 No. 5 ~ No. 8 Reserved
Set to "0".
SW-F1 No. 1, No. 2 DTMF detect time
Used to set detect time of DTMF (Dual Tone Multi Frequency) used in
remote reception (5 ).
The longer the detect time is, the less the error detection is caused by noises.
SW-F1 No. 3 Protection of remote reception (5 ![](/images/new-backgrounds/1122910/12291045xi4.webp)
) detect
Used to set the function of remote reception (5 ). When set to "1", the remote reception function is disabled.
SW-F1 No. 4 Remote reception with GE telephone
(Corresponding to TEL made by GE) P. B. X.
"1": Compatible with TEL mode by GE
"0": Not compatible
•When sending (5 ) for remote reception with a GE manufac- tured telephone remote reception may not take place because of special specifications in their DTMF.
To overcome this, a soft SW is provided to change the modem set- ting to allow for remote reception.
•If this soft SW is set to "1", other telephone sets may be adversely affected.
Remote operation codes can be changes from 0 through 9. If set to
greater than 9, it defaults to 9. The "5 | " is not changed. | ||
(Default: 5 | ) |
|
SW-F2 No. 1 CNG detection in STAND-BY mode
When setting to "1", the CNG signal detection function during standby stops.
SW-F2 No. 2, No. 3 Number of CNG detect (AM mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 4, No. 5 Number of CNG (STAND-BY mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 6 Fax signal detection after telephone mode dial
When set to "1", if machine detect the fax answering signal after tel- ephone calling (handset
SW-F2 No. 7, No. 8 Reserved
Set to "0".
SW-G1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-G2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-G3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-H1 No. 1 Busy tone detection ON/OFF time (Lower duration)
The initial value of detection is set according to electric condition.
The set value is changed according to the local switch board. (Erro- neous detection of sound is reduced.)
Normally the upper limit is set to 900msec, and the lower limit to 150msec.
If erroneous detection is caused by sound, etc., adjust the detection range.
The lower limit can be set in the range of 350msec to 150msec.
SW-H1 No. 2 Busy tone detection ON/OFF time (Upper duration)
Similarly to
The upper limit can be set in the range of 650msec to 900msec.
Detection range | ||
|
|
|
0 | 0 | 150msec ~ 900msec |
|
|
|
0 | 1 | 150msec ~ 650msec |
|
|
|
1 | 0 | 350msec ~ 900msec |
|
|
|
1 | 1 | 350msec ~ 650msec |
|
|
|
2 – 14