UX-258TH

FO-475TH

5.Soft switch description

• Soft switch

SW

DATA

ITEM

 

 

Switch setting and function

 

 

 

Initial

Remarks

NO.

NO.

1

 

 

 

 

 

0

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Protect from echo

No

 

 

 

 

Yes

 

 

 

 

0

 

 

2

Forced 4800 BPS reception

Yes

 

 

 

 

No

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Footer print

Yes

 

 

 

 

No

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Length limitation of copy/send/receive

No limit

 

 

 

 

Copy/send: 60cm

 

0

 

SW

 

 

 

 

 

 

 

 

Receive: 1.5m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l

5

CSI transmission

No transmitted

 

 

 

 

Transmitted

 

 

 

0

 

A1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

DIS receive acknowledgement during G3

Twice

 

 

 

 

NSF: Once

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

transmission

 

 

 

 

 

 

DIS: Twice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Non-modulated carrier for V29 transmission

Yes

 

 

 

 

No

 

 

 

 

0

 

 

 

modem

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

EOL detect timer

25 s

 

 

 

 

13 s

 

 

 

 

0

 

 

 

Modem speed

 

 

 

 

V.29

V.27 ter

 

 

 

 

 

 

9600bps

 

7200bps

4800bps

 

2400bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

No. 1

 

0

 

 

0

0

 

 

0

0

 

 

2

 

No. 2

 

0

 

 

0

0

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

3

 

No. 3

 

0

 

 

1

1

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

No. 4

 

1

 

 

1

0

 

 

0

1

 

l

 

 

 

 

 

 

 

A2

5

Sender’s information transmit

No

 

 

 

 

Yes

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

6

H2 mode

No

 

 

 

 

Yes

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Communication error treatment in RTN

No communication error

 

 

Communication error

 

0

 

 

 

sending mode (reception)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

CNG transmission

No

 

 

 

 

Yes

 

 

 

 

0

 

 

 

CED tone signal interval

 

1000ms

 

750ms

500ms

 

 

75ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

No. 1

 

1

 

 

1

0

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

No. 2

 

1

 

 

0

1

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

3

MR coding

No

 

 

 

 

Yes

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l

4

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

A3

5

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Signal transmission level

Binary input

 

 

 

 

 

 

0

 

 

2

 

No. = 16

8

4

2

1

 

 

 

 

 

0

 

SW

3

 

1

2

3

4

5

 

 

 

 

 

1

 

4

 

0

0

1

0

0 (-8 dBm)

 

 

 

 

0

 

l

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

0

 

A4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Protocol monitor (error print)

Printed at com. err

 

 

 

Not printed

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Protocol monitor

Yes

 

 

 

 

No

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Line monitor

Yes

 

 

 

 

No

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital line equalization setting (Reception)

 

 

 

7.2km

 

0km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

No. 1

 

 

 

1

 

 

 

0

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

No. 2

 

 

 

1

 

 

 

0

 

1

 

SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

A5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Reserved

 

 

 

 

 

 

 

 

 

 

 

0

 

 

7

Error criterion

10 ~ 20 %

 

 

 

 

 

5 ~ 10 %

 

 

 

0

 

 

8

Anti junk fax check

Yes

 

 

 

 

No

 

 

 

 

0

OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 – 5

Page 14
Image 14
Sharp UX-258TH, FO-475TH manual Soft switch description, Data, Option