[2] Diagnostics and service soft switch

1. Operating procedure

(1) Entering the diagnostic mode

Press FUNC 9 8 # 7 , and the following display will appear.

ROM Ver. FKD0 After 2 sec: DIAG MODE

FKD0

Then press the

START

key. Select the desired item with the

key or the # key or select with the rapid key. Enter the mode with the START key.

(Diagspecifications)

FUNC

9

8

7

 

FKD0

 

DIAG MODE

 

 

 

 

 

 

 

 

 

 

 

Soft switch mode

 

START

 

1

 

 

 

 

 

 

 

 

 

 

ROM & RAM check

 

START

 

2

 

 

 

 

 

 

 

 

 

 

Aging mode

 

START

 

3

 

 

 

 

 

 

 

 

 

 

Panel key test

 

START

 

4

 

 

 

 

 

 

 

 

 

 

Check pattern mode

 

START

 

5

 

 

 

 

 

 

 

 

 

 

Signal send mode

 

START

 

6

 

 

 

 

 

 

 

 

 

 

Memory clear mode

 

START

 

7

START

10

9 8

START Flash memory clear START Flash memory check

START

Entry data receive

 

Entry data send

START

 

 

START

Auto feeder mode

 

All black mode

START

 

Shading mode

START

If the diag mode cannot be set, repeat the diag mode operation, per- forming the following operation.

After the power is turned on and "ESPERE POR FAVOR" is indicated, press the STOP key.

STOP START

KEY KEY

"Power ON" +

+

Memory clear (Work + Backup)

In relation with the process response (request from Production Engineering) "ESPERE POR FAVOR" clock indication may appear depending on STOP key timing. If the STOP key is held down, "MEMORY CLEAR?" appears.

2. Diagnostic items

ITEM

DIRECT

Contents

Function

No.

key

 

 

 

 

 

 

1

1

SOFT SWITCH MODE

Soft switches are displayed and changed. List can be output.

 

 

 

 

2

2

ROM & RAM CHECK

ROM is sum-checked, and RAM is matched. Result list is output.

 

 

 

 

3

3

AGING MODE

10 sheets of check patterns are output every 5 minutes per sheet.

 

 

 

 

4

4

PANEL KEY TEST

Panel keys are tested. Result list is output.

 

 

 

 

5

5

CHECK PATTERN MODE

Check pattern is output.

 

 

 

 

6

6

SIGNAL SEND MODE

Various signals of FAX communication are output.

 

 

 

 

7

7

MEMORY CLEAR MODE

Back-up memory is cleared, and is set at delivery.

 

 

 

 

8

8

SHADING MODE

Shading compensation is performed in this mode.

 

 

 

 

9

9

ALL BLACK MODE

To check the print head, whole dots are printed over the interval of 2 m.

 

 

 

 

10

10

AUTO FEEDER MODE

Insertion and discharge of document are tested.

 

 

 

 

11

ENTRY DATA SEND

Registered content is sent.

 

 

 

 

12

ENTRY DATA RECEIVE

Registered content is received, and its list is output.

 

 

 

 

13

FLASH MEMORY CHECK

Flash memory is checked.

 

 

 

 

14

FLASH MEMORY CLEAR

Data of flash memory is cleared.

 

 

 

 