Sharp XG-C40XU operation manual Lamp/Maintenance Indicators

Models: XG-C40XU

1 63
Download 63 pages 21.84 Kb
Page 50
Image 50
Lamp/Maintenance Indicators

Lamp/Maintenance Indicators

Maintenance Indicators

POWER

LAMP

TEMPERATURE

indicator

REPLACEMENT

WARNING

 

indicator

indicator

The warning lights on the projector indicate problems inside the projector.

There are two warning lights: a TEMPERATURE WARNING indicator which warns that the projector is too hot, and a LAMP REPLACEMENT indicator which lets you know when to change the lamp.

If a problem occurs, either the TEMPERATURE WARNING indicator or the LAMP REPLACEMENT indicator will illuminate red. After turning off the power, follow the procedures given below.

Maintenance Indicator

Condition

Problem

Possible Solution

 

 

 

 

TEMPERATURE

The internal

• Blocked air intake.

• Relocate the projector to an area with

WARNING indicator

temperature is

 

proper ventilation.

 

abnormally high.

 

 

 

• Clogged air filter.

• Clean the filter.

 

 

 

(See page 47.)

 

 

 

 

 

 

• Cooling fan breakdown.

• Take the projector to your nearest

 

 

• Internal circuit failure.

Authorized Sharp Industrial LCD Products

 

 

 

Dealer or Service Center for repair.

 

 

 

 

LAMP REPLACE-

The lamp does not

Burnt-out lamp.

• Carefully replace the lamp. (See pages 50

MENT indicator

illuminate.

• Lamp circuit failure.

and 51.)

 

 

 

• Take the projector to your nearest

 

The lamp requires

• Lamp has been used for

 

Authorized Sharp Industrial LCD Products

 

replacement.

over 1,900 hours.

 

Dealer or Service Center for repair.

 

 

 

 

 

 

 

POWER indicator

The POWER

• The bottom filter cover is

• Securely install the bottom filter cover.

 

indicator flashes in

open.

 

 

red when the

 

 

 

projector is on.

 

 

 

 

 

 

&Troubleshooting

Maintenance

If the TEMPERATURE WARNING indicator illuminates, follow the above possible solutions and then wait until the projector has cooled down completely before turning the power back on. (At least 5 minutes.)

If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be triggered, preventing the power from going on. Should this occur, take the power cord out of the wall outlet and put it back in again.

Lamp

The lamp in this projector operates for approximately 2,000 cumulative hours, depending on the usage environ- ment. It is recommended that the lamp be replaced after 1,900 cumulative hours of use or when you notice a significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen Display (see page 43).

Maintenance IndicatorsCAUTION

Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.

As the usage environment can vary significantly, the projector lamp may not operate for 2,000 hours.

Condition

Problem

Possible Solution

The LAMP REPLACEMENT

• Lamp has been used for over 1,900

• Purchase a replacement lamp unit

indicator illuminates red, and

hours.

(lamp cage/module) of the current

“LAMP” and “

 

” will flash in yellow

 

type BQC-XGC40XU/1 from your

 

 

in the lower-left corner of the

 

nearest Authorized Sharp Industrial

picture.

 

LCD Products Dealer or Service

 

 

 

 

Center.

 

 

 

 

• Replace the lamp. (See pages 50

 

 

 

 

and 51.) If you wish, you may have

The power will automatically turn

• Lamp has been used for over 2,000

the lamp replaced at your nearest

off and the projector will enter

hours.

Authorized Sharp Industrial LCD

standby mode.

 

 

Products Dealer or Service Center.

 

 

 

 

 

 

 

 

“LAMP” and “Lamp” will flash in red in the lower-left corner of the picture, and the power will turn off.

E-49

Page 50
Image 50
Sharp XG-C40XU operation manual Lamp/Maintenance Indicators