Shindaiwa GP3410 manual Prior to Assembly, Install the Suction and Discharge Hoses, Priming

Models: 6850-9430 GP3410

1 60
Download 60 pages 17.19 Kb
Page 5
Image 5
Assembly

Assembly

Prior to Assembly

Before assembling this unit, make sure you have all the components required for a complete unit:

GP3410 engine-driven pump

Spark plug wrench

Spanner

3mm Hex Wrench

4mm Hex Wrench

Parts bag including:

1.0" hose clamps (3 each)

hose fittings and gaskets (2 each)

strainer

Install the Suction and Discharge Hoses

CAUTION!

 

 

Priming Port

 

This pump is intended for pumping

 

 

Discharge Port

 

 

 

 

fresh water only.

 

 

 

 

 

Ingested debris can damage the

 

 

Gasket

 

 

pump impeller and seals.

 

Ring Nut

Suction Port

 

 

Never operate the pump if the

 

 

 

 

 

 

 

 

 

strainer is missing or damaged.

 

Hose Clamp

 

 

 

. Assemble a barbed hose fitting, ring

 

 

 

 

 

nut, and gasket as shown, and thread

 

 

 

 

 

the completed hose fitting assembly

 

 

Barbed Hose

 

 

onto the pump suction port. Assemble

 

 

Fitting

 

 

the remaining hose fitting to the pump

 

 

 

 

 

discharge port.

 

 

 

 

 

. Push a 1.0" suction hose (not provided)

 

Suction

 

 

 

over the suction hose fitting on the pump

 

 

 

 

 

Hose

 

 

 

body, and secure with a 1.0" hose clamp as

 

 

Hose Clamp

 

Suction

shown. Working at the opposite end of the

Figure 1B

 

 

Strainer

suction hose, use a second 1.0" hose clamp

 

 

 

 

 

 

 

 

to install and secure the suction strainer.

4.

Install the discharge hose (not pro-

 

IMPORTANT!

3. Submerge the suction hose strainer in

 

 

vided) and secure with the remaining

Place the pump as close to the water

the water source. For maximum per-

 

1.0" hose clamp.

 

 

 

source as possible. Increases in suction

formance, avoid placing the strainer

5.

Recheck that both the suction and dis-

lift will lower pump performance. Do not

directly in heavy accumulations of

 

charge hoses are free from obstruc-

exceed maximum suction head of 26 feet.

leaves, silt, or other debris.

 

 

tions, and that all connections are

 

 

 

 

 

 

tightly secured.

Priming

Before the pump can develop suction or “lift” at the water source, the pump impeller must first be primed by filling the pump housing with water. Once the GP3410 has been primed, additional prim- ing should be required only if the pump has been drained or otherwise emptied.

. Remove the filler plug at the top of the pump housing. Use care not to lose the sealing ring beneath the filler plug.

IMPORTANT!

A damaged or missing filler plug seal may allow air to leak into the pump housing. Air leakage can lower performance!

. Fill the pump housing through the priming port (Figure 2) with clean water until water overflows from the filler plug hole on the pump body.

3.Replace and securely tighten the filler plug.

CAUTION!

Never allow the pump to run dry! Operation without water can perma- nently damage the pump seals.

Filler Plug

Sealing ring

Priming port

Figure 2

Page 5
Image 5
Shindaiwa GP3410, 6850-9430 manual Prior to Assembly, Install the Suction and Discharge Hoses, Priming