8.12.98

I_KAP03A.FM5

Gigaset 2060isdn, Inland:

A30853-X210-B101-1-19

Operation with other mobile units

System settings

Set device type

 

 

Cordless user (1-8)

B# 1SC*) O* 0 O (int. No.)

 

<device type> (1,2,3,4,6,7)**

Corded user (0)

B# 1SC*)

O* 0 O (int. No.)

 

<device type> (0,2,3,4,6,7)**)

Corded user (9)

B# 1SC*)

O* 0 O (int. No.)

 

<device type> (0,2,3,4,5,6,7)**)

Set internal collective call

B# 1SC*)

O* 5 <INT No.> 1/ 0B

Activate/deactivate dialing of * / #

B# 1SC*)

O# 5 1 / 0B

Activate/deactivate trunk hold

B# 1 SC*)

O# 7 1 / 0B

(2-channel three-party conference, point-to-

 

 

multipoint)

 

 

 

 

 

Activate/deactivate call transfer behind PBX

B# 1SC*)

O# 8 1 / 0B

Activate/deactivate permanent DTMF during

B# 1SC*)

O# 9 1 / 0B

connect

 

 

 

 

Unregister mobile unit

B# 7 2SC*) <INT No.> B

*) SC = system code of the base station (default code: “0000”)

**) 0 no function, 1 mobile unit, 2 telephone, 3 modem, 4 fax, 5 intercom, 6 neutral, 7 answering machine

Operation with door intercom (int. No. 9)

Set ring allocation

B# 1SC*) O# 6 <INT No.> B

Answer call and operate door opener

Ring from door c converse with party at door...

 

I 9 (door opener for 3 seconds.)

Answer call-waiting signal from door

Call... BR

*) SC = system code of the base station (default code: “0000”)

Multicell operation

Set multicell operation (all base stations)

B# 1SC*) O# * 0

(with basic access/behind PBX)

0/ 1 B

 

 

Permit handover

B1<base No.> B

Automatic handover

BI 0 B

Display base-station number

B3 6 1 B

Roaming when idle

automatic

 

 

Roaming when call in progress

Ext. call base station 1... # ext. call base station 2...

*) SC = system code of the base station (default code: “0000”)

66

Page 66
Image 66