6 Configuring and Programming the CP as a PROFINET IO Device

6.3Configuration

Configuring the CP as a PROFINET IO device involves the two following activities in STEP 7:

1.The CP is inserted in a SIMATIC 300 station in HW Config and enabled for PROFINET IO device mode in the properties dialog.

2.The CP is assigned to a PROFINET IO controller as a PROFINET IO device in HW Config.

Notice

These two configuration steps can be taken independently in HW Config. In both steps, make sure that the configured device name for the PROFINET IO device matches exactly.

6.3.1Installing the CP and Specifying it as PROFINET IO Device

Follow the steps below in STEP 7 / HW Config:

1.Take the required CP from the hardware catalog and insert the module in the SIMATIC 300 station.

Figure 6-2 Inserting the CP in a SIMATIC Station in HW Config