MAKING NETWORK CONNECTIONS

1000BASE-T Cable Requirements

All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, Category 5e (enhanced Category 5) or Category 6 cable should be used. The Category 5e specification includes test parameters that are only recommendations for Category 5. Therefore, the first step in preparing existing Category 5 cabling for running 1000BASE-T is a simple test of the cable installation to be sure that it complies with the IEEE 802.3-2005 standards.

1000 Mbps Gigabit Ethernet Cable Lengths

Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length

Cable Type

Maximum Cable

Connector

 

Length

 

 

 

 

Category 5, 5e, 6 100-ohm UTP or STP

100 m (328 ft)

RJ-45

 

 

 

Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Length

Fiber Size

Fiber

Maximum Cable

Connector

 

Bandwidth

Length

 

 

 

 

 

62.5/125 micron

160 MHz/km

2-220 m (7-722 ft)

LC

multimode fiber

 

 

 

200 MHz/km

2-275 m (7-902 ft)

LC

 

 

 

 

 

50/125 micron

400 MHz/km

2-500 m (7-1641 ft)

LC

multimode fiber

 

 

 

500 MHz/km

2-550 m (7-1805 ft)

LC

 

 

 

 

 

4-8