Appendix

Item number

Item

Setting

 

Function

612

VITC POSITION-2

12,281 line

 

When 29.97PsF/59.94i mode is selected on the VTR, this

 

select (NTSC)

 

 

setting specifies the lines in which the VITC signal is

 

 

[16,279 line]

 

inserted.

 

 

 

 

It can be inserted in any lines from 12,281 to 20,283.

 

 

20,283 line

 

 

 

 

 

 

 

Note

 

 

 

 

 

Items

611 and 612 allow VITC to be inserted in two lines.

 

 

 

 

 

613

TC OUTPUT

[off tape]

 

Specifies the signal output to the TIME CODE OUT

 

SIGNAL IN

regene

 

connector when the internal time code generator is in a

 

REGENE MODE

through

 

mode for regenerating the playback time code (i.e. during

 

 

 

 

auto edit mode or when item 607 is set to “int-LTC” and

 

 

 

 

item 606 is set to “regene”).

 

 

 

 

off tape: The playback time code signal is output to the

 

 

 

 

TIME CODE OUT connector without regeneration.

 

 

 

 

regene: The playback time code signal is output to the

 

 

 

 

TIME CODE OUT connector after regeneration only

 

 

 

 

when the VTR is in playback mode.

 

 

 

 

through: The time code signal input to the TIME CODE IN

 

 

 

 

connector is output as it is.

 

 

 

 

 

614

PHASE

[off]

 

Specifies whether the phase correction control of the LTC

 

CORRECTION

on

 

signal generated by the time code generator is applied or

 

 

 

 

not.

 

 

 

 

off: The phase correction control is not applied.

 

 

 

 

on: The phase correction control is applied.

 

 

 

 

 

616

VITC POSITION-1

9,322 line

 

When 25PsF/50i mode is selected on the VTR, this setting

 

select (PAL)

 

 

specifies the lines in which the VITC signal is inserted.

 

 

[19,332 line]

 

It can be inserted in any lines from 9,322 to 22,335.

 

 

22,335 line

 

 

 

 

Note

 

 

 

 

 

Items

616 and 617 allow VITC to be inserted in two lines.

 

 

 

 

 

617

VITC POSITION-2

9,322 line

 

When 25PsF/50i mode is selected on the VTR, this setting

 

select (PAL)

 

 

specifies the lines in which the VITC signal is inserted.

 

 

[21,334 line]

 

It can be inserted in any lines from 9,322 to 22,335.

 

 

22,335 line

 

 

 

 

Note

 

 

 

 

 

Items

616 and 617 allow VITC to be inserted in two lines.

 

 

 

 

 

618

LTC OUTPUT

input

 

Selects the LTC output phase.

 

PHASE select

auto

 

input: Same phase as input video.

 

 

[output]

 

auto: When editing, same phase as input video; otherwise

 

 

 

 

(playback, recording, etc.), same phase as output

 

 

 

 

video.

 

 

 

 

output: Same phase as output video.

 

 

 

 

 

619

EXT LTC MODE

direct

 

Selects the recording mode when the internal time code

 

 

[regene]

 

generator is set to regenerate the input from the TIME

 

 

 

 

CODE IN connector (menu item 607 is set to “ext-LTC”, and

 

 

 

 

menu item 606 is set to “regene”).

 

 

 

 

direct: Records the time code input from the TIME CODE

 

 

 

 

IN connector unaltered on the tape.

 

 

 

 

regene: Regenerates the time code input from the TIME

 

 

 

 

CODE IN connector with the internal time code

 

 

 

 

generator.

 

 

 

 

 

620

SUPERIMPOSED

[off]

 

Specifies whether or not to superimpose time data and

 

CHARACTER

on

 

operating status information on the signal output from the

 

 

 

 

MONITOR connector of SD SDI OUT, the SD OUT

 

 

 

 

COMPOSITE connector and HD SDI OUTPUT connector.

 

 

 

 

off: No information is superimposed.

 

 

 

 

on: Information is superimposed.

 

 

 

 

 

 

156 Menu List