Item number

Item

Setting

Function

A05

PD EXT SD REF

[off]

When the operating frequency is set to 23.98PsF, specifies

 

LOCK MODE

lock1

whether or not the pulldown output signal and down-

 

 

lock2

converted output signal are synchronized with the

 

 

 

reference signal by the REF. INPUT 2 connector.

 

 

 

off: The pulldown output signal and down-converted output

 

 

 

signal are not synchronized with the reference signal

 

 

 

by the REF. INPUT. 2 connector.

 

 

 

lock1: The pulldown output signal and down-converted

 

 

 

output signal are synchronized with the reference

 

 

 

signal by the REF. INPUT 2 connector.

 

 

 

lock2: The pulldown output signal and down-converted

 

 

 

output signal are synchronized with the reference

 

 

 

signal by the REF. INPUT 2 connector. When the PB/

 

 

 

EE mode is selected, the amount of delay on the A

 

 

 

frame of the pulldown output signal for the A frame of

 

 

 

the main video signal is fixed to 2 frames (59.94i).

 

 

 

Notes

 

 

 

 

A warning message appears when the HD reference

 

 

 

 

signal and REF. INPUT 2 reference signal are not input or

 

 

 

 

not synchronized.

 

 

 

“lock1” and “lock2” are effective only when the operation

 

 

 

 

mode of this unit is set to 23.98/24PsF.

 

 

 

When editing in 23.98/24PsF mode, with this unit as the

 

 

 

 

recorder and with “lock2” selected, phase

 

 

 

 

synchronization may not be achieved within 5 seconds.

 

 

 

 

Also, edit In points may be out of alignment. In these

 

 

 

 

cases, select “off”.

 

 

 

 

A06

PD

[off]

When item 620 and A03 is set to “on”, specifies whether or

 

SUPERIMPOSED

on

not the ID (24F/30F) is displayed to the right of

 

TIME CODE ID

 

superimposed time code.

 

 

 

off: No ID is displayed.

 

 

 

on: ID (“24F” or “30F”) is displayed.

 

 

 

Note

setting of this item is effective only when the operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The

 

 

 

 

 

 

 

 

 

 

 

 

mode of this unit is set to 23.98PsF or 24PsF.

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

 

 

 

 

A07

MODE

 

first line instead of 30-frame time data.

PD CHARACTER

[off]

When item 620 and A03 is set to “on”, specifies whether or

 

 

24F TIME CODE

on

not the 2 : 3 pulldown 24-frame time data is inserted to the

 

 

 

 

off: 30-frame time data is displayed.

 

 

 

 

on: 24-frame time data is displayed.

 

 

 

 

Note

 

 

 

 

The

setting of this item is effective only when the operation

 

 

 

mode of this unit is set to 23.98PsF or 24PsF.

 

 

 

 

A08

FC REFERENCE

extrn HD

Selects the signal to be the reference for the FORMAT

 

select

[extrn SD]

CONV. OUT input to the REF. INPUT 2 connector.

 

 

 

extrn HD: Use the HD tri-level reference signal input to the

 

 

 

REF. INPUT 2 connector as the FORMAT CONV. OUT

 

 

 

reference signal.

 

 

 

extrn SD: Use the SD reference signal input to the REF.

 

 

 

INPUT 2 connector as the FORMAT CONV. OUT

 

 

 

reference signal.

Menu List 177