Item number

Item

Setting

Function

A10

TC sense data

[LINE/24F]

Specifies whether or not the time code information of FC

 

select

FC/30F

output signal is returned when time code sense command

 

 

 

is input through the 9-pin connector.

 

 

 

LINE/24F: Time code information of main output signal is

 

 

 

returned. In pulldown conversion mode, 24-frame/sec

 

 

 

time code information is returned.

 

 

 

FC/30F: Time code information of FC output signal is

 

 

 

returned. In pulldown conversion mode, 30-frame/sec

 

 

 

time code is returned.

Notes

• Pulldown output signal and 30-frame/sec time code are synchronized only when this unit is set to PLAY LOCK mode. To synchronize the signals, set item A05 “PD EXT SD REF LOCK MODE” to “lock2”.

• When editing pulldown output signals with a VTR operating in 30F mode, it may not be possible to achieve sync within 5 seconds. If this occurs, set the preroll time to 7 seconds.

Also, normal operation is not possible with devices engaged in player sync.

Other Items (Nos. T01 to ...)

 

 

Item number

Item

Setting

Function

 

 

T01

AUTO REPEAT

[off]

Selects the repeating operation of PREVIEW in automatic

 

 

 

MODE

on

editing.

 

 

 

 

 

off: PREVIEW in automatic editing is not repeated.

 

 

 

 

 

on: PREVIEW in automatic editing is repeated. To stop,

 

 

 

 

 

press the STOP button.

 

 

 

 

 

 

 

 

T02

INTERNAL VIDEO

[off]

Selects the test signal output by the signal generator built

 

 

 

SIGNAL

COLOR BARS

into the VTR.

 

 

 

 

 

 

 

 

 

GENERATOR (HD)

MULTI BURST 1

off: The test signal is not generated, and the VTR operates

 

 

 

 

 

 

 

 

 

 

 

 

 

MULTI BURST 2

normally.

 

 

 

 

 

 

 

 

Appendix

 

10 STEPS

all other settings: The test signal is output from the VTR. At

 

PULSE & BAR

this time it is also possible to record the signal.

 

 

 

 

 

 

 

 

RAMP

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

T04

INTERNAL AUDIO

[off]

Selects the operation of audio test signal output.

 

 

 

SIGNAL

silence

off: The audio test signal is not output.

 

 

 

GENERATOR

1 kHz sine

silence: Mute signal.

 

 

 

 

 

1 kHz sine: 1 kHz (In this case, a 1 kHz -20 dB FS sine

 

 

 

 

 

wave is supplied to all audio inputs.)

Notes

• When “silence” or “1 kHz sine” is selected, the AUDIO IN and AUDIO MONITOR L/R buttons light up.

• When the unit is operated in the 23.98 PsF or 24 PsF mode with “1 kHz sine” selected, the output signal is 960 Hz.

Note

Items T01, T02, and T04 are reset to their factory default settings whenever the power is turned off.

178 Menu List