1 Press the SCH button on the vectorscope.
The vectorscope switches to SCH mode.
2 Press the B channel button on the vectorscope.
This displays the black burst signal from the switcher.
3 Press the EXT button on the vectorscope.
This switches the vectorscope to external synchronization mode.
4 Adjust the phase synchronization control on the vectorscope so that the sync and subcarrier phases are close to the reference line.
Sync phase
Subcarrier phase | Reference line |
Align the sync and subcarrier phases of the black burst signal to the reference line.
5 Output the player 1 signal.
6 Press the A channel button on the vectorscope.
| This displays the sync and subcarrier phases | |||||||
| ||||||||
| (composite signals only) of the signal from player 1. | |||||||
Chapter | ||||||||
7 On player 1, adjust the SYNC PHASE and SC PHASE | ||||||||
5 | controls on the menu control panel, using a Phillips | |||||||
SettingsandConnections | ||||||||
screwdriver, so that the output from player 1 on | ||||||||
| ||||||||
| channel A is in correct phase alignment with the black | |||||||
| burst signal on channel B. |
|
| |||||
|
|
|
|
|
|
| ||
|
| This indicator |
|
| This | indicator | ||
|
| |||||||
|
|
|
|
|
| |||
|
| moves as you | ||||||
|
| moves | as you | |||||
|
| turn the SYNC | ||||||
|
| turn the SC | ||||||
|
| PHASE control. | ||||||
|
| PHASE control. | ||||||
|
|
|
|
|
| |||
|
| Adjust the sync and subcarrier phases of the output | ||||||
|
| signal from player 1. |
|
| ||||
|
|
|
|
|
|
|
|
Note
When component signals are used the subcarrier phase indicator does not appear.
8 Output the player 2 signal and repeat steps 6 and 7 to adjust the sync and subcarrier phases of the output from player 2.
58 Adjusting the Sync and Subcarrier Phases