Location and Function of Parts and Controls

Control Panel

VOL –

 

VOL +

 

MENU

 

m

 

M

 

ENT

 

RGB1

 

YUV

 

RGB2

 

LINE

 

Y/C

 

CTRL

 

1

qd

qs

qa

0

9 8 7 6 5

4 3 2 1

1Remote control detector

Receives the beam from the Remote Commander.

21 (standby) switch/1 (standby) indicator Press to turn on the monitor. Press again to go back to the standby mode.

The 1 (standby) indicator lights up in red in the standby mode.

When the 1 indicator flashes, see “Self-diagnosis Function” on page 36 (GB).

3Power indicator

Lights up when the monitor is turned on.

4CTRL (control) button

To operate the buttons on the control panel, first press this button. When the buttons light up or flash that shows that they can be operated. Press again to deactivate them.

Note

The buttons (except for 1 (standby) switch 2) on the control panel do not function if you do not press the CTRL button first.

5Y/C button

Selects the signal input from the Y/C IN jack among the LINE connectors.

6LINE button

Selects the signal input from the VIDEO IN connector among the LINE connectors.

7RGB2 button

Selects the signal input from the RGB2 connectors.

8YUV button

Selects the component signal input from the RGB1 connectors.

9RGB1 button

Selects the RGB signal input from the RGB1 connectors.

0ENT (enter) button

Press to select the desired item from the menu displayed.

qa M/m buttons

Press to move the cursor (B) to an item or to adjust a value in a menu.

qs MENU button

Press to make the menu appear.

qd VOL (volume) +/– buttons

Press the + button to increase the volume, or the – button to decrease the volume.

8 (GB)