Administrating the Camera

Setting the Alarm Out 1 or 2

— Alarm out 1 or 2 setting Page

When you click Alarm out 1 on the Administrator menu, the Alarm out 1 setting page appears. When you click Alarm out 2 on the Administrator menu, the Alarm out 2 setting page appears.

Use these pages to set up for the Alarm out function that controls the alarm out 1 or alarm out 2 of the I/O port located on the rear the camera. You can control the alarm out when a trigger occurs by an external sensor input, the built-in activity detection function, a manual trigger button, the Day/Night function or the timer. The setting items for alarm out 1 and alarm out 2 are the same. This section explains how to set alarm out 1 as an example.

Activating/Deactivating the Alarm Out 1 Function

— Alarm out 1 usage setting Page

To activate the Alarm out 1 function, select Use alarm out 1 function and click OK. The Alarm out 1 setting page appears.

When you do not use the Alarm out 1 function, select Do not use alarm out 1 function and click OK.

Setting the Alarm Out 1 Function

— Alarm out 1 setting Page

Mode

Select the mode of the Alarm out 1 function.

Manual: Controls the alarm out 1 manually.

In this mode, you can short-circuit and open the alarm out 1 by clicking the (Trigger) button on the main viewer page. (See “Controlling the Application Manually” on page 13.)

Day/Night: Controls alarm out 1 by synchronizing with the Day/Night function of the camera. When you select Day/Night, the Day/Night setting button

appears. Click the button, and the Camera setting page appears and you can set the Day/Night function (see page 21).

In the Night mode, the relay corresponding to the alarm out 1 is short-circuited. In the Day mode, it is open.

Alarm: Controls alarm out 1 by synchronizing with an external sensor input or the built-in activity detection function. When you select Alarm, the Alarm mode setting section appears (see page 34).

Timer: Controls alarm out 1 by the timer. When you select Timer, the Timer mode setting section appears (see page 35).

Alarm mode setting Section

Alarm

Select the alarm to link the alarm out 1 function. If the selected alarm is detected, the alarm out 1 status changes.

Sensor 1: External sensor connected to sensor input 1 of the camera I/O port

Sensor 2: External sensor connected to sensor input 2 of the camera I/O port

Sensor 3: External sensor connected to sensor input 3 of the camera I/O port

Activity detection: The activity detection function built in the camera.

To set the activity detection function, click Activity detection. The Activity detection setting page appears (see page 40).

Available period

Select the period for which the alarm mode is available. Always: The alarm mode is available any time.

Use scheduler: The alarm mode is available according to the schedule selected on the Schedule No. menu below.

Schedule No.

When Use scheduler is selected on the Available period menu, select the schedule you want the alarm mode being available.

Click to select the check box(es) 1 to 6. You can select multiple schedules.

34

Setting the Alarm Out 1 or 2 — Alarm out 1 or 2 setting Page

Page 34
Image 34