8-2-5 Using the BKW-401 Viewfinder Rotation Bracket
By fitting a
Using the
To fit the
1 Turn the arm of the rotation mechanism assembly of the
2 Remove the two M3 ⋅ 10 hexagon socket bolts from
the
Hexagon socket bolts (M3 ⋅ 10)
3 Using a hexagonal wrench 2.5 mm across flats, detach the viewfinder shoe from the camcorder body.
4 Using the two bolts (M3 ⋅ 10) and washers removed in step 2, attach the rotation mechanism assembly of the
8-2-6 Detaching the Eyepiece
Removing the eyepiece gives a clearer view of the screen from further away. It is also easy to remove dust from the viewfinder screen and mirror when the eyepiece is detached.
1 Turn the eyepiece locking ring fully counterclockwise, to align the red marks on the locking ring and the viewfinder barrel.
Red mark
Red mark
Locking ring | Line up the red marks. |
2 Detach the eyepiece.