Structure of the paint adjustment data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-volatile memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

region

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER GAMMA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KNEE POINT

 

 

 

 

 

 

 

 

 

 

Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETAIL LEVEL

 

 

 

 

 

 

 

 

 

 

menu of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/B GAIN

 

 

 

 

 

 

 

 

 

 

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cam-

 

 

 

 

R/B BLACK

 

 

 

 

 

 

Hardware

 

 

corder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

camera

 

 

RM-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B150

 

 

 

 

Remote control data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

region

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER GAMMA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KNEE POINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETAIL LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/B GAIN

 

 

RM-B150

 

 

 

 

 

 

 

 

R/B BLACK

 

 

connected

 

 

 

 

 

 

 

 

 

 

 

 

 

or not

 

 

 

 

 

 

 

 

 

 

 

 

 

connected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

can use settings of the paint adjustment data stored in the independent data region even if you connect the remote control unit. In this case, the settings stored in the independent data region will be renewed when you change the settings on the remote control unit. Thus, the settings of the paint data made with the remote control unit can be retained even if the remote control unit is removed. However, if the switch position on the remote control unit differs from the one on the camcorder, the switch position on the camcorder takes precedence over that on the remote control unit.

Also, it is possible to keep the settings that are in effect before you connect the remote control unit. In this case, you should set the control knob to the relative value mode on the remote control unit.

For details, refer to the operation manual supplied with the remote control unit.

Camcorder the Up Setting 8 Chapter

As the illustration above shows, the non-volatile memory of the camcorder consists of two regions: one is the independent data region that becomes effective when the remote control unit is not connected, and the other is the remote control data region that becomes effective when the remote control unit is connected. Paint adjustment data is automatically selected depending on whether or not the remote control unit is connected to the camcorder.

Thus, when the remote control unit is connected to the camcorder, the effective data region is switched to the remote control data region and the settings of the paint adjustment that were in effect the last time the remote control unit was used are recalled.

Settings of the absolute value control knobs 1) and absolute value switches 2) are overwritten by those on the remote control unit after the remote control unit is connected.

1)Absolute value control knob

The data corresponding to the rotation degree (position) of the control knobs is output. The data corresponding to the rotation amount is called the relative value control knob.

2)Absolute value switch

Like the toggle switches or slide switches (except the momentary switches), the switches (or controls) whose positions must coincide with their functions are called absolute value switches.

When the remote control unit is removed from the camcorder, the independent data region becomes effective. Thus the camcorder will return to the settings that were in effect before the remote control unit was connected. When RM COMMON MEMORY is set to ON on the FUNCTION 3 page of the MAINTENANCE menu, you

128 8-10 Connecting the Remote Control Unit