TL H.264 DVR User’s Manual

5.6.5Alert Notification Setup

This function allows users to send alert notifications to the CMS program which had been installed to users’ computer. For detailed setup instruction, please refer to the CMS user’s manual.

 

Alert Notification Setup

 

1. Alert Configuration Set

1

2.

Alert Notification

OFF

3.

Alert IP

0.0.0.0

4. Alert Port

9999

5. Alive Interval

120 Sec

5.6.5.1Alert Configuration Set

<Alert Configuration Set> provides 3 combinations of Alert Notification, IP, and Port.

5.6.5.2Alert Notification

Four options are included in this item; <OFF>, <Event>, <Alive>, and <Both>.

<OFF>: The Alert Notification is turned off.

<Event>: When the alarm is triggered, the DVR will send an alert message to the CMS.

<Alive>: The DVR will send an alive message to the CMS every N second just to show you that the connection between the DVR and CMS is in effect. The time interval N can be adjusted in <Alive Interval>.

<Both>: This enables the DVR to send both Event and Alive alert messages to the CMS.

5.6.5.3Alert IP

The Alert IP must match the IP address of the computer.

5.6.5.4Alert Port

The ports for DVR and the CMS Alert MUST be the same.

5.6.5.5Alive Interval

Users can define the time interval (1 to 255 seconds) between each alive message.

75

Page 76
Image 76
Speco Technologies 4TL specifications Alert Notification Setup