Specifications and Dimensions
Specifications | 50 Pound |
|
| 75 Pound | F75 |
|
|
|
|
|
|
Noise level measured during | 63 dBA |
|
| 69 dBA | 67 dBA |
operation at operator position of |
|
|
|
|
|
3.3 feet (1 meter) in front of |
|
|
|
|
|
machine and 5.2 feet (1.6 meters) |
|
|
|
|
|
from floor. |
|
|
|
|
|
|
|
|
|
|
|
Net Weight (approximate): | 545 |
|
| 615 | 710 |
Pounds (kg) | (247) |
|
| (279) | (322) |
|
|
|
|
|
|
Cylinder Size: | 37 x 30 |
|
| 37 x 36 | 37 x 36 |
Inches (mm) | (940 x 762) |
|
| (940 x 914) | (940 x 914) |
|
|
|
|
|
|
Cylinder Capacity (dry weight): | 50 |
|
| 75 | 75 |
Pounds (kg) | (22.7) |
|
| (34) | (34) |
|
|
|
|
|
|
Air Outlet Diameter: | 8 |
|
| 8 | 10 |
Inches (mm) | (203) |
|
| (203) | (254) |
|
|
|
|
|
|
Maximum Static Back Pressure: | 0.5 |
|
| 0.5 | 0.5 |
W.C.I. (mbar) | (1.3) |
|
| (1.3) | (1.3) |
|
|
|
|
| |
Maximum Airflow: | 750 |
| Gas/Steam 60 Hz 920 (434) | 1100 | |
(354) |
| Gas/Steam 50 Hz 750 (354) | (518) | ||
C.F.M. (L/sec.) |
| ||||
|
| Electric | 750 (354) |
| |
|
|
|
| ||
|
|
|
|
|
|
Motor Horsepower: | 1/2 |
|
| 3/4 | N/A |
Nonreversing |
|
| |||
Reversing |
|
|
|
|
|
Fan | 1/3 |
|
| 1/3 | 1 |
Cylinder | 1/3 |
|
| 1/3 | 1/3 |
|
|
| |||
|
|
|
|
|
|
| Gas Models |
|
|
| |
|
|
|
|
|
|
Gas Connection | 1/2 in. NPT |
|
| 1/2 in. NPT | 3/4 in. NPT |
|
|
|
|
|
|
Gas Burner Rating: | 120,000 |
|
| 165,000 | 215,000 |
Btu/hr (Mj/hr) | (126.6) |
|
| (174.1) | (227) |
|
|
|
|
| |
| Electric Models |
|
| ||
|
|
|
|
|
|
Heating Element Rating: | 21 kW (240 V/50 Hz) |
|
| 30 kW | N/A |
Kilowatts (kW) | 30 kW (other voltages) |
|
|
|
|
|
|
|
|
| |
| Steam Models |
|
| ||
|
|
|
|
|
|
Steam Connection | 3/4 in. NPT |
|
| 3/4 in. NPT | N/A |
|
|
|
|
|
|
Steam Coil Rating: | 5.1 |
|
| 6.1 | N/A |
Boiler Horsepower (Btu/hr) | (177,500) |
|
| (210,300) |
|
|
|
|
|
|
|
N/A = Not Applicable
10 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | M414905 |