Electrical Requirements

75 Pound Gas and Steam Models

Refer to Table 8 and Table 9.

NOTE: Wire size and breaker ratings were obtained from the Canadian Electrical Code for 75 C. wire and are intended for use as a guideline only. Electrical connections should be made by a qualified electrical contractor in accordance with all applicable local and national requirements.

NOTE: Electrical specifications below are subject to change without notice. Always refer to product serial plate for most current specifications of product being installed.

NOTE: Use copper conductors only.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).

 

 

Terminal Block

Serial Plate Amps

Recommended Circuit

 

 

 

 

 

 

 

Serial Plate Rating

 

Connections

Nonreversing

Reversing

Breaker

Wire Size

 

 

Required

Rating

AWG (mm2)

120V/60Hz/1ph

 

L1, Neutral and ground

13.8

 

N/A

20A – 1 pole

12 (3.31)

 

 

 

 

 

 

 

 

 

200-208V/60Hz/1ph

 

L1, Neutral and ground

7.6

 

N/A

15A – 1 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

200-208-240V/60Hz/

 

L1, L2 and ground

7.6

 

N/A

15A – 2 pole

14 (2.08)

1ph

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/1ph

 

L1, Neutral and ground

6.7

 

7.0

15A – 1 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

200-208V/60Hz/3ph

 

L1, L2, L3 and ground

3.8

 

4.3

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

200V/50Hz/3ph

 

L1, L2, L3 and ground

3.5

 

4.5

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

240V/60Hz/3ph

 

L1, L2, L3 and ground

3.8

 

4.3

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

230-240V/50Hz/3ph

 

L1, L2, L3 and ground

3.5

 

4.9

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

380V/50 or 60Hz/3ph

 

L1, L2, L3 and ground

1.8

 

2.1

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

400-415V/50Hz/3ph

 

L1, L2, L3 and ground

1.8

 

2.1

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

440V/60Hz/3ph

 

L1, L2, L3 and ground

1.9

 

2.1

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

460-480V/60Hz/3ph

 

L1, L2, L3 and ground

1.9

 

2.1

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

N/A = Not Applicable

 

 

 

 

 

 

 

 

 

 

 

 

Table 8

 

 

 

F75 Gas Models Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Block

 

Serial Plate Amps

Recommended Circuit

 

 

 

 

 

 

 

 

Serial Plate Rating

 

Connections

 

Nonreversing

 

Reversing

Breaker

Wire Size

 

 

Required

 

 

Rating

AWG (mm2)

200-208V/60Hz/3ph

L1, L2, L3 and ground

 

N/A

 

6.3

15A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

240V/60Hz/3ph

L1, L2, L3 and ground

 

N/A

 

6.3

15A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

460-480V/60Hz/3ph

L1, L2, L3 and ground

 

N/A

 

3.1

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

 

 

 

N/A = Not Applicable

 

 

 

 

 

 

 

 

Table 9

M414905

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

45