Exhaust Requirements

1

2

I

J

K

L

L

K

J

I

 

CONTINUE

 

 

 

 

 

 

CONTINUE

TO A

 

 

 

 

 

 

TO A

 

 

TWO MANIFOLD ASSEMBLIES

3

 

 

 

 

 

 

TMB2018N

1

NOTE: Where the exhaust duct pierces a

2

Outlet duct diameter

 

combustible wall or ceiling, the opening

3

45° typical

 

 

MUST be sized per local codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 17

 

 

 

 

 

 

 

 

 

 

 

Duct

50/75 Pound

 

 

 

F75

 

 

 

 

 

Station

8 in. (203 mm) Duct

 

 

 

10 in. (254 mm) Duct

 

 

 

 

 

 

 

 

 

 

 

 

A

 

13 in. (330 mm)

 

 

 

15 in. (381 mm)

 

 

 

 

 

 

 

B

 

17 in. (432 mm)

 

 

 

22 in. (559 mm)

 

 

 

 

 

 

 

C

 

18 in. (457 mm)

 

 

 

26 in. (660 mm)

 

 

 

 

 

 

 

D

 

24 in. (610 mm)

 

 

 

30 in. (762 mm)

 

 

 

 

 

 

 

E

 

27 in. (686 mm)

 

 

 

34 in. (864 mm)

 

 

 

 

 

 

 

F

 

30 in. (762 mm)

 

 

 

37 in. (940 mm)

 

 

 

 

 

 

 

G

 

33 in. (838 mm)

 

 

 

40 in. (1016 mm)

 

 

 

 

 

 

 

H

 

34 in. (864 mm)

 

 

 

43 in. (1092 mm)

 

 

 

 

 

 

 

I

 

37 in. (940 mm)

 

 

 

46 in. (1168 mm)

 

 

 

 

 

 

 

J

 

39 in. (991 mm)

 

 

 

47 in. (1194 mm)

 

 

 

 

 

 

 

K

 

40 in. (1016 mm)

 

 

 

50 in. (1270 mm)

 

 

 

 

 

 

 

L

 

42 in. (1067 mm)

 

 

 

51 in. (1295 mm)

 

 

 

 

 

 

 

Table 4

M414905