Adjustments
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the tumbler before servicing.
•Close gas
•Close steam valve to steam tumbler before servicing.
•Never start the tumbler with any guards/ panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
W002
Gas Burner Air Shutter
NOTE: Air inlet shutters on the burner must be adjusted so sufficient air is metered into the system for proper combustion and maximum efficiency. Before adjusting the inlet shutters be sure that all lint is removed from lint compartments and lint screen.
Air shutter adjustments will vary from location to location and will depend on the vent system, number of units installed,
Refer to Figure 25.
1.Open the access panel.
2.Start the tumbler and check the flame pattern. If the flame pattern is straight up, insufficient air is flowing through the tumbler and airflow switch is improperly set. A flame pattern that flares to the right and left indicates no air is flowing through the tumbler. Correct air and gas mixture is indicated if the flame pattern is primarily blue, with small yellow tips, and bends to the right of the heater section. Too little air is indicated if the flame if yellow, lazy and smokey.
3.To adjust the air shutter, loosen air inlet shutter adjusting screw.
4.Open or close air shutter as necessary to obtain proper flame intensity.
5.After air shutter is adjusted for proper flame, tighten air shutter adjusting screw securely.
PROPER AIRFLOW
1
INSUFFICIENT AIRFLOW
1
NO AIRFLOW
1
T457I
1Air Shutter Adjusting Screws
Figure 25