Installation

 

 

 

 

 

 

 

 

 

 

 

 

SupplyBurner

 

 

 

Burner

Country

 

 

OrificeCapacity/

Diameter,

 

Gas TypeGroupPressure,Quantity

Orifice

Code

Pressure,

Model

mm

 

 

mbar

 

Part No.

 

 

 

mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DK/NO/

Natural Gas

H

20

8.9

050

3.7

2

M401000

 

 

 

 

075

3.6

3

M401014

SE/FI/CZ/

 

 

 

 

EE/LV/LT/

L.P. Gas

B/P

30

No Governor

050

2.1

2

M401003

SI/SK

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

E

20

8.9

050

3.7

2

M401000

 

 

 

 

 

075

3.6

3

M401014

 

 

 

 

 

 

 

 

 

 

 

LL

25

12.6

050

3.7

2

M401000

DE**

 

 

 

 

075

3.6

3

M401014

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

No Governor

050

2.1

2

M401003

 

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

 

B/P

50

28.5

050

2.1

2

M401003

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

Natural Gas

L

25

12.6

050

3.7

2

M401000

NL

 

 

 

 

075

3.6

3

M401014

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

No Governor

050

2.1

2

M401003

 

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

Natural Gas

E+

20/25

No Governor

050

3.0

2

M401017

BE/FR*

 

 

 

 

075

2.9

3

N/A

 

 

 

 

 

 

 

 

L.P. Gas

+

28/37

No Governor

050

2.1

2

M401003

 

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

GB/IE/PT/

Natural Gas

H

20

8.9

050

3.7

2

M401000

 

 

 

 

075

3.6

3

M401014

ES/IT/GR/

 

 

 

 

 

 

 

 

L.P. Gas

+

28/37

No Governor

050

2.1

2

M401003

LU/CH

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

20

8.9

050

3.7

2

M401000

AT**

 

 

 

 

075

3.6

3

M401014

 

 

 

 

 

 

 

 

L.P. Gas

B/P

50

28.5

050

2.1

2

M401003

 

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

CY/IS/MT

L.P. Gas

B/P

30

No Governor

050

2.1

2

M401003

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

25

8.9

050

3.7

2

M401000

HU

 

 

 

 

075

3.6

3

M401014

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

No Governor

050

2.1

2

M401003

 

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

20

8.9

050

3.7

2

M401000

PL

 

 

 

 

075

3.6

3

M401014

 

 

 

 

 

 

 

 

L.P. Gas

3P

37

No Governor

050

2.1

2

M401003

 

 

 

 

 

 

075

2.0

3

M400999

 

 

 

 

 

 

 

 

 

Table 1

Burner orifice information at 0-2000 feet (0-600 meters) altitude.

N/A = Part no longer available.

*For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifice(s).

**For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model, M411334 regulator spring kit and burner orifice(s).

M414905

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT