Steam Requirements

2

1

11

 

12

 

6

 

3

 

4

 

13

 

5

10

 

9

 

8

 

7

 

6

TMB2014N

 

 

TMB2014N

NOTE: Refer to Table 11 for sizing of steam lines. Piping must also be sized accordingly for length of runs,

and number of elbows.

 

1

Supply

8

18 in. (457 mm) Drop

2

12 in. (305 mm) Riser

9

Solenoid Valve (Supplied with machine)

3

Shut-Off Valve

10

Steam Bonnet

4

Condensate Return Line from Supply Line

11

Flexible Line

5

Return

12

Union

6

Check Valve

13

Trap with Built-In Strainer

7Vacuum Breaker (Optional)

Figure 23

Steam Pressure PSI (bar)Minimum Pipe DiameterSteam Trap Size*
(Pounds Condensate/Hour)

 

 

 

 

 

80 – 100 (5.3-6.9)

3/4 in. NPT

160

 

 

 

*Based on 100 psi.

Table 11

M414905