Installation

Pre-Installation Inspection

Materials Required (Obtain Locally)

Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is

All Models

One Single Pole fused disconnect switch or circuit breaker on 1 Phase models.

Circuit breaker on 3 Phase models.

signed, or advise the carrier of the condition as soon as it is discovered.

Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.

Gas Models

One gas shut-off valve for gas service line to each tumbler.

One steam shut-off valve for steam service line to be connected upstream of solenoid steam valve.

Two steam shut-off valves for each condensate return line.

Flexible steam hoses with a 125 psig (pounds per square inch gauge)

IMPORTANT: Remove the shipping tape from the two back draft dampers located in the exhaust outlet.

IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed in this manual and applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.

Steam Models (8.79 kg/sq. cm) working pressure for connecting steam coils. Refer to Figure 23 for sizing and connection configurations.

Two steam traps for steam coil outlets to condensate return line.

Optional – Two vacuum breakers for condensate return lines.

IMPORTANT: Keep tumbler area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

NOTE: 3 Phase Only – Each tumbler must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).

16