Electrical Requirements

50 Pound Gas and Steam Models

Refer to Table 7.

NOTE: Wire sizes were obtained from the Canadian Electrical Code for 75 C. wire and are intended for use as a guideline only. Electrical connections should be made by a qualified electrical contractor in accordance with all applicable local and national requirements.

NOTE: Electrical specifications below are subject to change without notice. Always refer to product serial plate for most current specifications of product being installed.

NOTE: Use copper conductors only.

NOTE: 3 Phase Only – Each tumbler must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).

7

 

Terminal Block

Serial Plate Amps

Recommended Circuit

 

 

 

 

 

Serial Plate Rating

Connections

Nonreversing

Reversing

Breaker Rating

Wire Size

 

Required

AWG (mm2)

120V/60Hz/1ph

L1, Neutral and ground

9.3

N/A

15A – 1 pole

14 (2.08)

 

 

 

 

 

 

200-208V/60Hz/1ph

L1, Neutral and ground

5.1

N/A

10A – 1 pole

14 (2.08)

 

 

 

 

 

 

200-208-240V/60Hz/

L1, L2 and ground

5.1

N/A

10A – 2 pole

14 (2.08)

1ph

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/1ph

L1, Neutral and ground

6.3

6.9

15A – 1 pole

14 (2.08)

 

 

 

 

 

 

200-208V/60Hz/3ph

L1, L2, L3 and ground

2.8

4.0

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

200V/50Hz/3ph

L1, L2, L3 and ground

3.3

4.2

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

240V/60Hz/3ph

L1, L2, L3 and ground

2.8

4.0

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

230-240V/50Hz/3ph

L1, L2, L3 and ground

3.1

4.3

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

1.6

2.0

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

400-415V/50Hz/3ph

L1, L2, L3 and ground

1.6

2.0

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

440V/60Hz/3ph

L1, L2, L3 and ground

1.4

1.9

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

460-480V/60Hz/3ph

L1, L2, L3 and ground

1.4

1.9

10A – 3 pole

14 (2.08)

 

 

 

 

 

 

N/A = Not Applicable

 

 

 

 

 

Table 7

44

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT