Installation

Basic Configuration

1.Determine the necessary conversion operations to convert from the factory-supplied configuration to the desired configuration.

2.Perform the conversions required so the machine is properly configured for the desired country and gas (refer to Specific Conversion Procedures section):

How to Convert Gas Valve from Regulated to Unregulated

NOTE: Conversion from regulated to unregulated is only needed when regulated tumblers were ordered, but unregulated tumblers were needed.

How to Change Burner Orifice Size

How to Adjust Gas Valve Governor/Regulator

3.If applicable, peel off the appropriate country sticker (included with machine) and apply it to the serial plate over the existing country information.

4.If applicable, peel off the appropriate conversion sticker (included with machine) and apply it to the serial plate over the “ADJUSTED FOR

______ GAS: ______” information.

5.Commission tumbler for use.

WARNING

When converting the tumbler to a different gas or pressure, first verify that the supply inlet pressure is equipped with a pressure regulator (located ahead of the tumbler) that will maintain the gas supply at the inlet pressure specified.

W430

SPECIFIED

LOCAL INLET

PRESSURE

2

3

1

T103K

1Gas Shut-Off Valve (Ahead of pressure tap)

2Pressure Tap

3Gas Shut-Off Valve (Shown in closed position)

Figure 11

Specific Conversion Procedures

How to Convert Gas Valve from Regulated to Unregulated

NOTE: Conversion from regulated to unregulated is only needed when regulated tumblers were ordered, but unregulated tumblers were needed.

Johnson G96 Gas Valve:

a. Disconnect electrical power from tumbler. Close gas shut-off valve to tumbler. Refer to Figure 11.

b. Follow instructions in Conversion Kit, Part No. M400763 (Johnson Part No. Y71AA-5C).

NOTE: This kit does not contain any burner orifices.

c. Replace burner orifice(s) as per Table 1.

d. Commission tumbler for use.

26

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414905