Location Requirements
The tumbler must be installed on a level floor. Floor covering materials such as carpeting or tile should be removed.
To assure compliance, consult local building code requirements. The tumbler must not be installed or stored in area where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the rear of the tumbler with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note the minimum and maximum dimensions. Local codes and ordinances must be complied with.
WARNING
To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
W055
IMPORTANT: Install tumblers with sufficient clearance for servicing and operation, refer to Figure 1.
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.
|
|
|
|
|
|
|
| W056 |
|
|
|
|
|
| |||
1 | 3 | 4 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
5
6
7 TMB2131N
8
TMB2131N
NOTE: Shaded areas indicate adjacent structure.
10.5 in. (13 mm) recommended between machines for removal or installation
2Allow
34 in. (102 mm) maximum header thickness
412 in. (305 mm) minimum clearance permitted for remainder
5Guard
6Provision for
724 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
80.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed
Figure 1
M414905 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 17 |