Installation
1
13
12
11
2
10
9
8 7
6 | 3 |
4
5
TMB1527N
1 | Burner | 8 | |
2 | Gas Valve | 9 | Manifold Pipe |
3 | Regulator Plate | 10 | Spud Holder |
4 | Gasket | 11 | Pressure Tap |
5 | Plate | 12 | Burner Orifice |
6 | Regulator Cap | 13 | Burner Tube Openings |
7Spud Holder Nut
Figure 12
How to Change Burner Orifice Size
1.Disconnect electrical power from tumbler. Close gas
2.Remove spud holder.
Johnson G96 Gas Valve – Unscrew spud holder nut near gas valve. Remove the burner orifice(s) from spud holder. Refer to Figure 12.
3.Install the new, correct burner orifice(s). Refer to Figure 13 and Table 1. Torque each to 9 – 10 Nm.
4.Reinstall spud holder assembly to gas valve, making certain burner orifice(s) are in line with burner tube opening. Refer to Figure 13.
5.Commission tumbler for use.
NOTE: Blank burner orifices are Part No. M400995.M414905 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 27 |