3.20 Trouble shooting

...............................................................................................

41

3.20.1 Instructions for re-using and disposal

43

3.20.1.1

Re-use

43

3.20.1.2

Disposal

43

3.21 Maintenance instructions

43

3.21.1

General.

...........................................................................................................

43

3.21.2

Preparation

43

 

3.21.2.1

Surroundings (on site)

43

 

3.21.2.2

Tools

44

 

3.21.2.3

Shut-down

44

 

3.21.2.4

Motor safety

44

 

3.21.2.5

Conservation

44

 

3.21.2.6

External cleaning

44

 

3.21.2.7

Electrical installation

44

 

3.21.2.8

Draining of fluid

44

 

3.21.2.9

Fluid circuits

45

3.21.3

Specific components

45

 

3.21.3.1

Nuts and bolts

45

 

3.21.3.2 Plastic or rubber components

45

 

3.21.3.3

Flat gaskets

45

 

3.21.3.4 Filter or suction strainer

46

 

3.21.3.5

Anti-friction bearings

46

 

3.21.3.6

Sleeve bearings

46

3.21.4

Front pull-out

46

3.21.5

Back pull-out

46

3.21.6

Clearance adjustment

46

3.21.7 Designation of threaded connections

48

 

3.21.7.1 Threaded connection Rp (example Rp 1/2)

48

 

3.21.7.2 Threaded connection G (example G 1/2)

48

4.0

Instructions for assembly and disassembly

49

 

4.1

General

49

 

4.2

Disassembly

49

 

 

4.2.1 Disassembly of front-pull-out assembly

49

 

 

4.2.2 Disassembly of top cover (0100) or safety relief valve

50

 

 

4.2.3 Disassembly of bearing bracket

50

 

 

4.2.4 Disassembly of pump shaft complete

51

 

 

4.2.5 Disassembly of outer magnetic rotor

51

 

 

4.2.6 Disassembly of separation can

52

 

 

4.2.7 Disassembly of back-pull-out assembly

52

 

4.3

Assembly

54

 

 

4.3.1 Assembly of bearing bracket

54

 

 

4.3.2 Pre-assembly of the back-pull-out

56

 

 

4.3.2.1 Adjustment of the axial clearance of the circulation pump

56

 

 

4.3.2.2 Assembly of rotor shaft

57

 

 

4.3.3 Assembly of the back-pull-out assembly to the pump casing

59

 

 

4.3.4 Assembly of the separation can

59

 

 

4.3.5 Assembly of the bearing bracket

60

 

 

4.3.6 Assembly of the front-pull-out assembly

60

 

 

4.3.7 Assembly of top cover (0100) or safety relief valve

61

A.0500.551 – IM-TGMAG/02.00 EN (02/2008)

5

Page 5
Image 5
SPX Cooling Technologies TG MAG185-125 Instructions for re-using and disposal 20.1.1, 20.1.2, Maintenance instructions

TG MAG86-100, TG MAG23-65, TG MAG58-80, TG MAG15-50, TG MAG185-125 specifications

SPX Cooling Technologies has established itself as a leader in the design and manufacturing of cooling systems, offering a wide range of products tailored to meet specific industrial and commercial needs. Among its impressive lineup, the TG MAG series stands out, featuring models such as TG MAG185-125, TG MAG23-65, TG MAG86-100, TG MAG58-80, and TG MAG15-50. Each of these models combines innovative technology with robust performance characteristics, making them ideal choices for various applications.

The TG MAG185-125 model is designed for high-capacity cooling requirements, offering exceptional thermal performance while maintaining energy efficiency. Its advanced fan design minimizes noise levels, making it suitable for installations in noise-sensitive areas. Furthermore, the unit benefits from a corrosion-resistant construction, ensuring longevity and reliable operation in diverse environments.

For smaller applications, the TG MAG23-65 provides a compact solution without compromising on performance. This unit features a space-efficient design and utilizes high-efficiency fans that optimize airflow, thereby enhancing overall cooling efficiency. The integrated digital controls allow for precise temperature management, making it easy for operators to monitor and adjust settings as needed.

The TG MAG86-100 model serves as an ideal middle-ground solution, balancing capacity and efficiency. It incorporates state-of-the-art technology, such as variable speed drives, which adjust the fan speed based on cooling demand, resulting in significant energy savings. The design also promotes easy maintenance, with accessible components that facilitate regular servicing and inspections.

For medium-scale needs, the TG MAG58-80 combines durability with performance, featuring a robust frame that can withstand harsh operational conditions. Its efficient heat exchange technology maximizes cooling output while minimizing energy consumption. Moreover, the enhanced airflow system ensures uniform cooling across the entire unit.

Lastly, the TG MAG15-50 is perfect for smaller spaces where cooling requirements are less demanding. Despite its size, this model is equipped with cutting-edge features such as a compact structure and highly efficient cooling mechanisms to ensure effective performance. The easy installation process and low maintenance needs further enhance its appeal.

Overall, the TG MAG series provides a range of innovative cooling solutions tailored to meet diverse industrial requirements, characterized by efficiency, durability, and advanced technology, ensuring optimal performance across all operating conditions.