SPX Cooling Technologies TG MAG58-80 1.0Introduction, 1.1General, TopGear, stamped on a nameplate

Models: TG MAG86-100 TG MAG23-65 TG MAG58-80 TG MAG15-50 TG MAG185-125

1 72
Download 72 pages 42.17 Kb
Page 7
Image 7
1.0Introduction

1.0Introduction

1.1General

This instruction manual contains necessary information on the TopGear pumps and must be read carefully before installation, service and maintenance. The manual must be kept easily accessible to the operator.

Important!

The pump must not be used for other purposes than recommended and quoted for without consulting your distributor.

Liquids not suitable for the pump can cause damages to the pump unit, with a risk of personal injury.

1.2Reception, handling and storage

1.2.1Reception

Remove all packing materials immediately after delivery. Check the consignment for damage immediately on arrival and make sure that the name plate/type designation is in accordance with the packing slip and your order.

In case of damage and/or missing parts, a report should be drawn up and presented to the carrier at once. Notify your distributor.

All pumps have the serial number

TopGear

stamped on a nameplate.

Model: TG

This number should be stated in

 

 

 

 

all correspondence with your distributor.

 

 

The first two digits of the serial

 

 

number indicate the year of production.

 

 

Serial No:

 

 

 

 

 

SPX Process Equipment BE NV

 

Evenbroekveld 2-4

 

BE-9420 Erpe-Mere

 

www.johnson-pump.com and spxpe.com

1.2.2Handling

Check the mass (weight) of the pump unit. All parts weighing more than 20 kg must be lifted using lifting slings and suitable lifting devices, e.g. overhead crane or industrial truck. See section 6.6 Weights – Mass.

Always use two or more lifting slings. Make sure they are secured in such a way as to prevent them from slipping. The pump unit should be lifted in a horizontal position.

Never lift the pump unit with only two fastening points. Incorrect lift can cause personal injury and/or damage to the pump unit.

1.2.3Storage

If the pump is not commissioned immediately, the shaft should be turned a full turn once every week. This ensures a proper distribution of the protective oil.

A.0500.551 – IM-TGMAG/02.00 EN (02/2008)

7

Page 7
Image 7
SPX Cooling Technologies TG MAG58-80, TG MAG15-50 1.0Introduction, 1.1General, 1.2Reception, handling and storage, TopGear