Radial clearance on rotor, idler outside diameter – Axial clearance on pump cover
Pump size | CO (µm) | C1 (µm) | C1 (µm) | C2 (µm) | C3 (µm) |
| axial clear. | normal | normal |
|
|
| set minimum |
|
|
|
|
|
|
|
|
|
|
Code Rotor |
| 1xxx |
| 2xxx | 3xxx |
Code Idler |
|
| x1xx | x2xx | x3xx |
Code pump | xxx0 |
| xxx1 | xxx2 | xxx3 |
cover assembly |
|
|
|
|
|
TG MAG | 52 | 280 | 160 | 350 | 480 |
|
|
|
|
|
|
TG MAG | 56 | 290 | 170 | 375 | 510 |
|
|
|
|
|
|
TG MAG | 66 | 325 | 200 | 440 | 600 |
|
|
|
|
|
|
TG MAG | 72 | 340 | 220 | 480 | 660 |
|
|
|
|
|
|
TG MAG | 85 | 380 | 255 | 560 | 765 |
|
|
|
|
|
|
Please note:
On TG MAG pumps the radial rotor clearance C1 is slightly larger than on other TopGear pump families, while clearance class C2 and C3 are identical with the standard range.
Diametral clearance on pin / idler bearing
Pump size | C1 (µm) | C2 (µm) | C3 (µm) | |
normal | = 2 x C1 | = 3 x C1 | ||
| ||||
Code for adapted 6 material pin (2 or 3) *) | xx1x | xx2x | xx3x | |
Code for adapted bronze idler bush (Y or Z ) **) | xx1x | xxYx | xxZx | |
|
|
|
| |
TG MAG | 150 | 300 | 450 | |
TG MAG | 160 | 320 | 480 | |
|
|
|
| |
TG MAG | 240 | 480 | 720 | |
TG MAG | 275 | 550 | 825 | |
|
|
|
| |
TG MAG | 325 | 650 | 975 |
The extra clearances are realised as follows:
Rotor and Idler: | By extra machining of outside diameter (code 2, 3); | |
| or standard = 1 | |
Pump cover: | By adjusting during assembly (code 0, 2 , 3); | |
| or standard = 1 | |
Idler pin / bush bearing; | 2 cases are possible: (standard = 1) | |
| *) | case 1: by providing a special pin (6 material) with |
|
| adapted pin diameter (code 2 or 3) |
| **) | case 2: by providing a special bronze bush with adapted |
|
| inside bush diameter (code Y or Z). |
3.14 Play between gear teeth
Play between gear teeth
TG MAG | |||||
|
|
|
|
|
|
Minimum (µm) | 360 | 400 | 400 | 400 | 440 |
|
|
|
|
|
|
Maximum (µm) | 720 | 800 | 800 | 800 | 880 |
3.15 Maximum size of solid particles
TG MAG |
| |||||
|
|
|
|
|
|
|
Size (µm) | 80 |
| 120 | 150 | ||
|
|
|
|
|
|
|
If there are metal particles in the liquid, customer must install a magnetic filter before the liquid reaches the pump.
If there are hard particles in the liquid, consult your distributor.
A.0500.551 – | 21 |