SPX Cooling Technologies TG MAG185-125 Mass moment of inertia, Axial and radial clearances

Models: TG MAG86-100 TG MAG23-65 TG MAG58-80 TG MAG15-50 TG MAG185-125

1 72
Download 72 pages 42.17 Kb
Page 20
Image 20
3.11 Mass moment of inertia

3.11 Mass moment of inertia

TG MAG pump size

15-50

23-65

58-80

86-100

185-125

 

 

 

 

 

 

J (10-3 x kgm²)

3.5

6.8

32

54

200

 

 

 

 

 

 

Outer parts

Inner parts

Inner parts:

Idler

Rotor shaft

Axial rotor bearings

Shaft sleeve

Inner magnetic rotor

Outer parts:

Pump shaft

Outer magnetic rotor

 

 

 

Mass moment of inertia J [ 10-3x kgm2]

 

 

 

 

 

 

 

 

 

 

 

 

 

TG MAG

outer parts per lenght of magnets

inner parts per lenght of magnets

type

40/60

 

100

 

120

40/60

 

80

 

100

 

120

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15-50

22

26

-

 

-

8

 

9

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

23-65

22

26

-

 

-

10

 

12

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

58-80

66

80

93

 

-

46

 

52

 

58

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

86-100

72

85

99

 

-

65

 

70

 

76

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

185-125

248

303

358

 

413

230

 

247

 

264

 

280

 

 

 

 

 

 

 

 

 

 

 

 

 

3.12 Axial and radial clearances

 

 

 

TG MAG pump size

 

 

 

 

 

 

 

 

 

 

15-50

23-65

58-80

86-100

185-125

 

 

 

 

 

 

 

radial clearance

max (µm)

310

320

370

380

420

 

 

 

 

 

 

 

 

min (µm)

250

260

300

300

340

 

 

 

 

 

 

 

axial clearance

max (µm)

200

215

250

275

320

 

 

 

 

 

 

 

 

min (µm)

120

125

150

165

190

 

 

 

 

 

 

 

3.13 Extra clearances

To handle extra clearances following clearance classes are defined:

C0

=

Pump cover axial clearance set at minimum

C1

=

Standard clearance (not indicated because standard)

C2

=

~2 x standard clearance

C3

=

3 x standard clearance

To indicate required clearances a code of 4 digits, xxxx, is given on the order. The figure ‘‘1’’ stands always for ‘‘normal’’ and no special action is considered.

The indicated numbers in the tables below are average values in microns (µm).

20

A.0500.551 – IM-TGMAG/02.00 EN (02/2008)

Page 20
Image 20
SPX Cooling Technologies TG MAG185-125 Mass moment of inertia, Axial and radial clearances, Extra clearances, Inner parts