2.2 Use as directed
lThe servo amplifiers are components which are built into electrical equipment or machines,
and can only be used as integral components of such equipment.
lThe manufacturer of the machine must generate a hazard analysis for the machine, and take
appropriate measures to ensure that unforeseen movements cannot cause injury or damage to
any person or property.
lThe SERVOSTAR 600 family of servo amplifiers can be connected directly to symmetrically
earthed (grounded) three-phase industrial mains supply networks [TN-system, TT-system with
earthed (grounded) neutral point, not more than 5000rms symmetrical amperes, 480VAC ma-
ximum].
The servo amplifiers must not be operated directly on power supply networks >230V without
an earth (ground) or with an asymmetrical earth (ground).
Connection to different mains supply networks (with additional isolating transformer)ðp.48.
lPeriodic overvoltages between outer conductor (L1, L2, L3) and housing of the servo amplifier
may not exceed 1000V (peak value).
Transient overvoltages (< 50µs) between the outer conductors may not exceed 1000V.
Transient overvoltages (< 50µs) between outer conductors and housing may not exceed
2000V.
lIf the servo amplifiers are used in residential areas, or in business or commercial premises,
then additional filter measures must be implemented by the user.
lThe SERVOSTAR 600 family of servo amplifiers isonly intended to drive specific brushless
synchronous servomotors,with closed-loop control of torque, speed and/or position. The rated
voltage of the motors must be at least as high as the DC bus link voltage of the servo amplifier.
lThe servo amplifiersmay onlybe operated in a closed switchgear cabinet, taking into account
the ambient conditions defined on page19 and the dimensions shown on page 36. Ventilation
or cooling may be necessary to prevent enclosure ambient from exceeding 45°C (113°F).
lUse only copper wire. Wire size may be determined from EN 60204 (or table 310-16 of the
NEC 60°C or 75°C column forAWG size).
lWe only guarantee the conformance of the servo amplifiers with the standards for industrial
areas (page11), if the components (motors, cables, amplifiers etc) are delivered by Danaher
Motion.
lConsider the specifications on page92 when you use the optional personnel safe restart lock
-AS-.
Safetyinstructions
10 SERVOSTAR®601...620 Product ManualSafety 07/2007 Danaher Motion