Regen circuit: technical data SERVOSTAR
Supply
voltage Rated data DIM 601- 603 606- 620
3 x 230 V
Upper switch-on level of regen circuit V 400 - 430
Switch-off level of regen circuit V 380 - 410
Overvoltage F02 V 450
Continuous power of regen circuit (RBint) W 80 200
Continuous power of regen circuit (RBext)max. kW 0.25 0.75
Pulse power, internal (RBintmax. 1s) kW 2.5 5
Pulse power, external (RBextmax. 1s) kW 5
External regen resistor W33
3 x 400 V
Upper switch-on level of regen circuit V 720 - 750
Switch-off level of regen circuit V 680 - 710
Overvoltage F02 V 800
Continuous power of regen circuit (RBint) W 80 200
Continuous power of regen circuit (RBext)max. kW 0.4 1.2
Pulse power, internal (RBintmax. 1s) kW 8 16
Pulse power, external (RBextmax. 1s) kW 16
External regen resistor W33
3 x 480 V
Upper switch-on level of regen circuit V 840 - 870
Switch-off level of regen circuit V 800 - 830
Overvoltage F02 V 900
Continuous power of regen circuit (RBint) W 80 200
Continuous power of regen circuit (RBext)max. kW 0.5 1.5
Pulse power, internal (RBintmax. 1s) kW 10.5 21
Pulse power, external (RBextmax. 1s) kW 21
External regen resistor W33
Suitable external regen resistors can be found in our accessories manual.
SERVOSTAR®601...620 Product Manual 23
Danaher Motion 07/2007 Technical description