9.6 Error messages
Errors which occur are shown in coded form by an error number in the LED display on the front
panel. All error messages result in theBTB/RTO contact being opened, and the output stage of the
amplifier being switched off (motor loses all torque). If a motor-holding brake is installed, it will be
activated.
Number Designation Explanation
E/S/A/P Status Messages Status messages, no error, see p.86
... Status Message Updating the startup configuration
-Status Message Programming mode
F01* Heat sink temperature Heat sink temperature too high
limit is set by manufacturer to 80°
F02* Overvoltage Overvoltage in DC bus link
limit depends on the electrical supply voltage
F03* Following error Message from the position controller
F04 Feedback Cable break, short-circuit, short to ground
F05* Undervoltage Undervoltage in DC bus link
limit is set by manufacturer to 100V
F06 Motor temperature Motor temperature too high or temp. sensor defect
limit is set by manufacturer to 145°C
F07 Internal voltage supply Internalamplifier supply voltages are out of tolerance
F08* Overspeed Motor runs away, speed is too high
F09 EEPROM Checksum error
F10 Flash-EPROM Checksum error
F11 Brake Cable break, short-circuit, short to ground
F12 Motor phase Motor phase missing (cable break or similar)
F13* Internal temperature Internal temperature too high
F14 Output stage Faultin the power output stage
F15 I²t max. I²tmaximum value exceeded
F16* Supply BTB/RTO 2 or 3 phases missing in the mains supply feed
F17 A/D converter Error in the analog-digital conversion, normally caused by
extreme electromagnetic interferences.
F18 Regen Regen circuit faulty or incorrect setting
F19* Supply phase A phase is missing in the mains supply power feed
(can be switched off for 2-phase operation)
F20 Slot fault Slot error (hardware fault on expansion card)
F21 Handling error Software error on the expansion card
F22 Earth short circuit For40/70 amps type only
F23 CAN-bus off Severe CAN bus communication error
F24 Warning Warning is displayed as fault
F25 Commutation error Commutationerror
F26 Limit switch Homingerror (machine has driven onto hardware limit
switch)
F27 AS Operational error with -AS- , input for AS-Enable and EN-
ABLE have been set at the same time
F28 External Trajectory Externalposition profile generator created a step, that ex-
ceeded the maximum value
F29 Slot Fault depends on expansion card, see online help
F30 Emergency timeout Timeout emergency stop
F31 Macro Macro program error
F32 System Error systemsoftware not responding correctly
*= These error messages can be cancelled by the ASCII command CLRFAULT,without executing a reset. If
onlythese errors are present, and the RESET button or the I/O-function RESET is used, the CLRFAULT com -
mandis also all that is carried out.
More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter ERRCODE. Hints for removal can be found in section
"Trouble-Shooting" of the online help.
88 SERVOSTAR®601...620 Product ManualSetup 07/2007 Danaher Motion