9.8 Removing faults/warnings
Depending on the conditions in your installation, there may be a wide variety of reasons for the
fault. In multi-axis systems there may be further hidden causes of a fault.

Detailled hints for removal of faults can be found in the Online help chapter

"Trouble-Shooting".

Our customer service can give you further assistance with problems.
Fault possible causes Measures to remove the cause of
the fault
HMI message:
communication
fault
wrong cable used
cable plugged into wrong position
in servo amplifier or PC
wrong PC interface selected
use null-modem cable
plug cable into the correct
sockets on the servo amplifier
and PC
select correct interface
motor does not
rotate
servo amplifier not enabled
break in setpoint cable
motor phases swapped
brake not released
drive is mechanically blocked
no. of motor poles set incorrectly
feedback set up incorrectly
apply enable signal
check setpoint cable
correct motor phase sequence
check brake control
check mechanism
set no. of motor poles
set up feedback correctly
motor oscillates
gain too high (speed controller)
shielding in feedback cable is broken
AGNDnot wired up
reduceKp (speed controller)
replace feedback cable
joinAGND to CNC-GND
drive reports
following error
—I
rms orI peak is set to low
setpoint ramp is too long
increaseIrms or Ipeak
(keep within motor data !)
shorten setpoint ramp +/-
motor overheat-
ing —I
rms/Ipeak set too high reduceIrms/Ipeak
drive too soft
Kp(speed controller) too low
Tn (speed controller) too high
PID-T2 too high
T-Tacho too high
increaseKp (speed controller)
use motor default value for
Tn (speed controller)
reduce PID-T2
reduce T-Tacho
drive runs
roughly
Kp(speed controller) too high
Tn (speed controller) too low
PID-T2 too low
T-Tacho too low
reduceKp (speed controller)
use motor default value for
Tn (speed controller)
increase PID-T2
increase T-Tacho
axis drifts at
setpoint = 0V
offset not correctly adjusted for
analog setpoint provision
AGNDnot joined to the CNC-GND
of the controls
adjust setpoint-offset (analogI/O)
joinAGND and CNC-GND
90 SERVOSTAR®601...620 Product Manual
Setup 07/2007 Danaher Motion