8.3.2 Technical data for connecting cables
Further information on the chemical, mechanical and electrical characteristics of the cables can be
obtained from our customer service.

Observe the restrictions in the chapter "Conductor cross-sections" on page 20.

To reach the max. permitted cable length, you must use cable material that

matches the capacitance requirements listed below.

Insulation material
Sheathing PUR (polyurethane, code 11Y)
Core insulation PETP (polyesteraphtalate, code 12Y)
Capacitance
Motor cable less than 150 pF/m
RES-/Encoder-cable less than 120 pF/m
Technical data
For a detailed description of cable types and how to assemble them, please refer to the accessories
manual.

Motor cables longer than 25m with motor choke 3YL only.

8.3.3 Shielding connection to the front panel
42 SERVOSTAR®601...620 Product Manual
Electrical Installation 07/2007 Danaher Motion
Removethe outer covering of the cable
andthe shielding braid from the cores
forthe required length. Secure the cores
witha cable tie.
Removethe outer covering of the cable
overa length of about 30mm, without
damagingthe shielding braid.
Pulla cable tie through the slot in the
shieldingrail (front panel) of the servo
amplifier.
Usethe cable tie to clamp the shielding
braidof the cable firmly to the shielding
rail.
SERVOSTAR 600
SERVOSTAR 600