Programmer's Guide

PcOS Series 150

Control Codes

 

 

 

Vertical Motion

Function

Set form length in lines

 

ASCII

[ESC] C <n>

 

 

Hexadecimal

1BH 43H <n>

 

 

Decimal

<27> <67> <n>

 

IPCL

&%SL <m1> <m2>

 

EPOS

[ESC] C <n>

 

 

Description

This command sets the form length to <n> lines at the current line spacing.

Function

Set form length in inches

 

ASCII

[ESC] C [NUL] <n>

 

Hexadecimal

1BH 43H <0> <n>

 

Decimal

<27> <67> <0> <n>

 

IPCL

&%SI <m1> <m2>

 

EPOS

none

 

 

Description

This command sets the form length to <n> inches.

 

Function

Begin auto line feed

 

ASCII

[ESC] 5 <01>

 

 

Hexadecimal

1BH 35H 01H

 

 

Decimal

<27> <53> <01>

 

IPCL

&%MA

 

 

EPOS

none

 

 

Description

This command sets auto line feed mode.

 

 

Note: This overrides the configuration setting.

 

Function

End auto line feed

 

ASCII

[ESC] 5 <0>

 

 

Hexadecimal

1BH 35H 00H

 

 

Decimal

<27> <53> <0>

 

IPCL

&%CA

 

 

EPOS

none

 

 

Description

This command ends auto line feed mode.

 

 

Note: This overrides the configuration setting.

 

Function

Reverse line feed

 

ASCII

[ESC] ]

 

 

Hexadecimal

1BH 5DH

 

 

Decimal

<27> <93>

 

 

IPCL

&%LR

 

 

EPOS

none

 

 

Description

This command performs a reverse line feed at the current line spacing.

 

Note: The receipt station can tolerate no more than 1/2 inch of reverse feed.

Note: This command is not available in models with validation.

12/14/99

Rev G

Page 21

Page 31
Image 31
Star Micronics 150 manual Function Set form length in lines