Control Codes

PcOS Series 150

Programmer's Guide

Validation Operation

Validation Operation

The form is inserted from the top and extends out the left side and/or top of the printer. It rests on a fixed stop. A maximum of 16 lines at 40 characters can be printed on a form. In this manual, top insertion will be termed validation mode.

Function

Open for validation

ASCII

[ESC] [DC1]

Hexadecimal

1BH 11H

Decimal

<27> <17>

IPCL

&%VO

EPOS

[ESC] c 0 <n>

Description

This command opens the form compensation assembly for validation. No

 

automatic validation form sensing is performed. The application must poll

 

the printer for validation forms present and then issue a close

 

compensation command.

Function

Close for validation

ASCII

[ESC] [DC3]

Hexadecimal

1BH 13H

Decimal

<27> <19>

IPCL

&%VC

EPOS

[ESC] c 0 <n>

Description

This command closes the form compensation assembly for validation. No

 

automatic validation form sensing is performed.

Function

Close for validation when form is sensed

ASCII

[ESC] [DC4]

Hexadecimal

1BH 14H

Decimal

<27> <20>

IPCL

&%VS

EPOS

[ESC] c 0 <n>

Description

This command closes the form compensation assembly for automatic

 

validation form sensing by the printer.

Page 52

Rev G

12/14/99

Page 62
Image 62
Star Micronics 150 manual Validation Operation