Control Codes PcOS Series 150 Programmer's Guide
EPOS Deviations
Page 74 Rev G12/14/99
Function Set bar code
ASCII [GS] k <m> {information} [NUL]
Description The Series 150 Printer uses the same print functions to print EPOS bar
codes as the normal mode bar codes.
EPOS has two formats for bar codes. One is [NUL] terminated; the
other has a length field. If <m> is greater than 64, the next byte sets
the length in bytes. Only the [NUL] terminated command is supported
by the Series 150 Printer.
Where m 0UPC A Numeric (0-9) only, 11 digits maximum
1UPC E Numeric (0-9) only, 11 digits maximum
2EAN-13 Numeric (0-9) only, 12 digits maximum
3EAN-8 Numeric (0-9) only, 6 digits maximum
4Code 39 26 uppercase letters (A-Z), 10 digits (0-9)
5Interleaved 2 of 5 Numeric (0-9) only, must be even number of
digits
Note: If Code 128 is to be printed, it must be printed with the [ESC] b
<n> command as described on page 48.