95741 Sixth Edition 5-27
Error and Recovery

Clearing CSL Errors

Refer to the following process to clear CSL errors. Follow the directions
explicitly.
Note: Any time the operator indicator is flashing or on solid, clear the obvious
error. Refer to Table 5-5 on page 5-11 for a description of the operator
indicator.
1. After correcting the error, press the Start switch (Figure 5-17 on page 5-23,
call out 14) to clear the operator indicator.
2. If pressing the Start switch did not clear the indicator, press the Start switch
twice.
Note: Press the Start switch twice when there is a load failure or solid
operator indicator (red) on the CSL. Pressing the switch twice re
initializes the CSL.
3. If pressing the Start switch twice did not clear the operator indicator, power
cycle the CSL to bring it back online. Refer to Power On/Off CSL on
page 5-12 to correctly power cycle the CSL. Figure 5-20 on page 5-27 shows
the location of the power switch.
4. If power cycling the CSL did not clear the operator indicator, the CSL must
be replaced by a qualified technician.
Figure 5-20. CSL Rear View
1. Power switch
2. Power cord
3. SCSI cable
4. Terminator
C5366
1
41
2
3