Fibre Channel Change Configuration
6-18 Sixth Edition 95741
VolSafe Selection Submenu
VolSafe Y
VolSafe N
Defaults to last saved selection.
When VolSafe Y is selected, a
password (Contact StorageTek
Technical Support) must also be
entered before VolSafe is enabled.
When VolSafe N is selected,
VolSafe is disabled.
1. Press Menu to bypass, or
2. Press Select to toggle option;
then, press Menu to set.
3. If applicable, press Select to start
password entry. The left-most
character begins flashing.
4. Press Select to increment until
desired character is displayed,
then press Menu to set.
5. Repeat step 4 for each character.
6. Press
Menu
to advance to the next
submenu;
or
, press
Select
to restart.
Note: Manufacturing ships drive with the VolSafe N option selected.
Full Code Load Submenu
FullCode Y
FullCode N
Defaults to last saved selection.
When FullCode Y is selected,
all available drive code images
are downloaded to the EEPROM.
This enables the drive to be used
to create a code tape with all
images which then could be used
to update other drives.
When FullCode N is selected,
only the specific code image for
the drive is downloaded to
EEPROM. This option allows
more EEPROM space for dumps
and event logs, but disables the
drive from creating code tapes.
1. Press Menu to bypass, or
2. Press Select to toggle option;
then, press Menu to set, and
advance to the next submenu.
Note: Manufacturing ships drive with only one code image, and FullCode N selected.
CodCrFail3
displays if you try to make a code tape from a drive with only one
image loaded. (
Code release level 1.30.109 and up, displays CHK A738.)
To enable a drive to create code tapes, select FullCode Y, and load the desired
code release level from a valid source.
Table 6-1. Menu TableFibre Channel Configuration (Continued)
Options Notes Procedure