8-l-4 VOLTMETER

When AC voltage (1OOV)is loaded between the two terminals on the rear side of the volt- meter, and at the same time, the voltmeter shows the value, the voltmeter is normal.

Fig. 8-l-4

8-2 DIODE STACK (RECTIFIER)

(Orange)

0

 

(White)

 

 

 

0

(Yellow)

0

-

(Brown)

 

cl

 

 

Fig 8-2-l

Fig. 8-2-2

Fis. 8-2-3

 

 

 

Circuit inside the diode stack is as shown in Fig. 8-2-l. Confirm continuity between each terminal by using a circuit tester as shown in Fig. 8-2-3. The rectifier is normal when continuity is confirmed as follows.

I

Connect black s

terminal of the circuit tester

I

 

 

I

 

 

Yellow

;

White

.

Orange

Brown

No continuity ; Continuity

Connect red 0 terminal of the circuit tester

I

Table 8-2- 1

Note 1: In checking the diode, direction of connection is contrary to the ordinary case because of characteristics of the diode and battery incorporated in the tester.

Note 2: “Continuity” means forward direction characteristics of the diode, and, different from short circuit condition (in which a pointer of the tester goes out of its normal scale), shows resistance to some extent. Whenresults of the checking indicates failure even in

one section, replace with Assy.

- 23 -

Page 27
Image 27
Subaru Robin Power Products R1200 service manual One section, replace with Assy