Symptoms

D-lNo DC voltage is output

(

D-2 Voltag,eistoo high

1

qParts

qPossible causes

I

2 I

Checking method

LRemedies

I

Stator DC coil

1.Disconnection

2.Short circuit

I

Measure the resistance value between the terminals with a circuit tester (Measure at the section where diodes are connected)

In case of OQbl ...

Disconnection

In case of Oil ...

Short circuit

rReplace the stator

I

Diode stack

The diode is defective

I

Confirm continuity between the terminals with a circuit tester

Refer to 8-2) “Diode stack”

Replace the diode stack

I

Lead line

Disconnection of the lead line

Measure continuity with a circuit tester

In case of 00 51,the lead line is defective.

Replace the lead line

AVR

AVR failure

Measure resistance value between the terminals with a circuit tester (Measure with a 4P coupler)

If the resistance is different from the standard, replace the AVR

rpm of the engine increases too much (Frequency is too

Measure rpm at the rated load

50Hz: 3000+30rpm

60Hz: 3600”30rpm

Regulate rpm

L