8.FUNCTIONAL CHECK OF EACH COMPONENT
Check continuity between the two terminals at the rear of the AC receptacles by using a circuit tester under the condition that the receptacle is mounted on the control panel. When continuity between the output terminals is confirmed with a wire connected across the terminals, and is not confirmed if the wire is removed, the AC receptacle is normal.
Fig. | Fig. 8- I- 1 (b) |
Check continuity between the DC terminals at the rear of the receptacle by using a circuit tester, under the condition that the receptacle is mounted on the control panel.
When continuity between the DC terminals of the receptacle is confirmed with a wire con- nected across the terminals, and is not con- firmed if the wire is removed, the DC recept- acle is normal.
Fig.
Check continuity between the two terminals at the rear side of the circuit breaker by using a circuit tester under the condition that the circuit breaker is mounted on the control panel.
If continuity is confirmed when the breaker is ON, and no continuity is confirmed when the breaker is OFF, the circuit breaker is normal.
F&J.