9-3 CIRCUIT BREAKER
Check continuity between each of two terminals at the rear of the circuit breaker while it is mounted on the control panel. Normally, there is continuity between each of the two when the circuit breaker is on while there is no continuity when the circuit breaker is off.
Fig.
9-4 STATOR
Disengage connectors on the wires from stator and check the resistance between wires with a “Dr. Robin” or a circuit tester refering to the following table.
|
|
|
| Fig. | ||
MODEL | Specification | AC | Winding |
| 1 | |
Voltage | White/Red | I | Black/ Blue | I | ||
Hz 1 | ||||||
50 | 110v,220v,110v/220v | 1.85 |
| 1.85 |
| |
240V | 2.10 |
| 2.10 |
| ||
RGXl800 |
|
| ||||
220v,110v/220v | 1.10 |
| 1.10 |
| ||
60 |
|
| ||||
12OV,12OV/24OV | 1.10 |
| 1.10 |
| ||
|
|
| ||||
50 | 11ov,22ov,11ovi22ov | 1.18 |
| 1.18 |
| |
240V | 1.42 |
| 1.42 |
| ||
RGX2400 |
|
| ||||
220v,110v/220v | 0.84 |
| 0.84 |
| ||
60 |
|
| ||||
12OV,12OVl24OV | 0.84 |
| 0.84 |
| ||
|
|
| ||||
50 | 110v,220v,110v/220v | 0.73 |
| 0.73 |
| |
240V | 0.83 |
| 0.83 |
| ||
RGX3500 |
|
| ||||
220v,110v/220v | 0.69 |
| 0.69 |
| ||
60 |
|
| ||||
12OV,12OVl24OV | 0.69 |
| 0.69 |
| ||
|
|
| ||||
50 | 110v,220v,11 OVl22OV | 0.34 |
| 0.34 |
| |
240V | 0.41 |
| 0.41 |
| ||
RGX5500 |
|
| ||||
22ov, 11OVl22OV | 0.26 |
| 0.26 |
| ||
60 |
|
| ||||
12OV,12OVl24OV | 0.26 |
| 0.26 |
| ||
|
|
|
Table 9- 1
TOR
Condenser Winging
Yellow / Yellow
5.56
5.56
3.80
3.80
3.34
3.37
2.51
2.51
1.81
1.83
1.52
1.52
0.81
0.78
0.58
0.58
NOTE: If the circuit tester is not sufficiently accurate, it may not show the values given and may give erroneous readings.
Erroneous readings will also occur when there is a wide variation of resistance among coil windings or when measurement is performed at ambient temperatures different from 20°C(68”F).
- 49 -