(1) Using a “Dr. Robin” or a circuit tester, measure the resistance of the field coil at the terminals.
|
|
|
|
|
| (RXlQ | &lo%) |
MODEL | RGX1800 | RGX2400 | RgEy | Rgzy | RGXSOO | ||
|
|
|
|
|
| ||
RESISTANCE | 2.5 Q | 2.7 $2 |
| 2.1 R | 2.2 R |
| 1.6 R |
|
|
| Table |
|
|
|
NOTE 1: Because a diode is soldered to the coil ends at the terminals, resistance may be measured only when tester probes touche the terminals in one combi- nation of polarity. Therefore, if no re- sistance reading appears, try checking in reverse polarity.
NOTE 2: If the circuit tester is not sufficiently accurate, it may not show the values given and may give erroneous readings.
Erroneous reading will also occur when there is a wide variation of resistance
among coil windings or when meas-Fig.
peratures ditferent from 20°C(68”F).
Use a “Dr. Robin” in capacitance meter mode to check the capacity of condensers. (See
n.
RGXl800, RGX2400 | RGX3!500 | RGX5!500 |
Fig.
n
NOTE: Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance,or the accurate reading cannot be obtained.