9-5 ROTOR ASSEMBLY

(1) Using a “Dr. Robin” or a circuit tester, measure the resistance of the field coil at the terminals.

 

 

 

 

 

 

(RXlQ

&lo%)

MODEL

RGX1800

RGX2400

RgEy

Rgzy

RGXSOO

 

 

 

 

 

 

RESISTANCE

2.5 Q

2.7 $2

 

2.1 R

2.2 R

 

1.6 R

 

 

 

Table 9-2

 

 

 

NOTE 1: Because a diode is soldered to the coil ends at the terminals, resistance may be measured only when tester probes touche the terminals in one combi- nation of polarity. Therefore, if no re- sistance reading appears, try checking in reverse polarity.

NOTE 2: If the circuit tester is not sufficiently accurate, it may not show the values given and may give erroneous readings.

Erroneous reading will also occur when there is a wide variation of resistance

among coil windings or when meas-Fig. 9-5urement is performed at embient tem-

peratures ditferent from 20°C(68”F).

9-5 CONDENSER

Use a “Dr. Robin” in capacitance meter mode to check the capacity of condensers. (See Fig.9-6).

n.

,-I

RGXl800, RGX2400

RGX3!500

RGX5!500

Fig. 9-6

n

NOTE: Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance,or the accurate reading cannot be obtained.