Check the generator by following Step
Check the fuse in the fuse holder.
If the fuse is blown, check for the cause of fuseFUS blowing, and then replace with a new one.
FUSE : 10A
NOTE: If the DC output is used to charge a large capacity battery or an overdis- charged battery, an excessive current may flow causing fuse blow.
Check all the wires to be connected correctly.
Remove the control panel and check the diode rectifier with a circuit tester.
Refer to Section
Fig.
Check the resistance between two brown leads from stator with a circuit tester.
MODELSPECIFICATIONRESISTANCE
50Hz | 11OV, 22OV, 24OV, 11OVl22OV | 0.41 !a |
RGXl800 | 12OV, tiOV, 11OVl22OV, 12OV/24OV | 0.3552 |
60Hz |
I |
| 50Hz | 11OV, 22OV, 24OV, 11OVl22OV | 0.298 |
| RGX2400 | - 60Hz | 12OV, 22OV, 11OV/22OV,12OVl24OV | 0.278 |
| RGX3!500 | 50Hz | 11OV, 22OV, 24OV, 11OVl22OV | 0.26R |
| 60Hz | 12OV, 22OV, 11OVl22OV, 12OVl24OV | 0.2251 | |
|
| |||
| RGX5!500 | 50Hz | 11OV, 22OV, 24OV, 11OVl22OV | 0.1552 |
|
| 60Hz | 12OV, 22OV, 11OVl22OV, 12OVl24OV | 0.1452 |
Table 1
If the resistance reading is much larger or smaller than the specified value, the DC coil of the stator is faulty. Replace stator with a new one.