Subaru Robin Power Products RGXI 800, RGX5500, RGX3500, RGX2400 manual nNORMAL CAPACITY OF CONDENSER

Models: RGX2400 RGXI 800 RGX3500 RGX5500

1 94
Download 94 pages 63.35 Kb
Page 54
Image 54
nNORMAL CAPACITY OF CONDENSER

nNORMAL CAPACITY OF CONDENSER

MODEL

RGXl BOO

RGX2400

RGX3500

RGX5500

014,xF20,~F17fiFX228,~FX2

Resistance

0

14,~F

20,~F

17pFX2

28fiFX2

Table 9-3

HIf such an instrument is unavailable, the condenser can be checked by replacing with a new one.

If the generator performs good with new condenser, the cause of trouble is defect in original condenser.

9-7 DIODE RECTIFIER

DIODE RECTIFIER

Brown/

Orange

 

 

 

White

 

 

 

 

 

 

 

 

Orange

0

II

Brown

 

 

 

 

 

 

 

 

Brown

0

II

Brown/White

 

rl

 

CIRCUIT TESTER

Fig. 9-9

Fig. 9-10

Circuit inside of the diode rectifiers is as shown in Fig. 9-9. Check continuity between each terminal by using a circuit tester as shown in Fig. 9-10. The rectifier is normal when condtinuity is as follows:

H Checking table for analogue circuit tester.

 

Analogue circuit tester

Apply black @needle of the circuit tester

 

Brown

Brown

Orange

BrownMlhite

I

 

 

 

 

 

Brown

 

No continuity

No continuity

Continuity

 

 

 

I

I.

I

I

Apply

red @

needle

Brown

No continuity

 

 

 

 

 

 

 

 

of the

circuit

tester

Orange

Continuity

 

 

 

 

 

 

 

 

 

 

 

 

Brown/White

No continuity

 

 

 

 

 

 

 

Table 9-4-l

 

 

 

- 51 -

Page 54
Image 54