Chapter 5: Advanced Serverboard Setup

HDD LED

The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. Refer to the table on the right for pin defi nitions.

NIC1 LED

The NIC1 (Network Interface Control- ler) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity. Refer to the table on the right for pin defi nitions.

NIC2 LED

The NIC2 (Network Interface Control- ler) LED connection is located on pins 9 and 10 of JF1. Attach the NIC2 LED cable to display network activity. Refer to the table on the right for pin defi nitions.

Overheat/Fan Fail LED (OH)

Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad- vanced warning of chassis overheat- ing. Refer to the table on the right for pin defi nitions.

Power Fail LED

The Power Fail LED connection is located on pins 5 and 6 of JF1. Re- fer to the table on the right for pin defi nitions.

HDD LED

Pin Definitions (JF1)

Pin# Defi nition

13Vcc

14HD Active

NIC1 LED

Pin Definitions (JF1)

Pin# Defi nition

11Vcc

12Ground

NIC2 LED

Pin Definitions (JF1)

Pin# Defi nition

9Vcc

10

Ground

 

 

OH/Fan Fail LED

Pin Definitions (JF1)

Pin# Defi nition

7Vcc

8Ground

Power Fail LED

Pin Definitions (JF1)

Pin# Defi nition

5Vcc

6Ground

5-13

Page 47
Image 47
SUPER MICRO Computer 6015B-8+ manual Overheat/Fan Fail LED OH, Power Fail LED